Skip to main content
GW125-PCS-N-G10 vs S6-EH3P100K10-NV-YD-H 9 of 18 identical Swap Change inverters

GoodWe GW125-PCS-N-G10 vs Ginlong Solis S6-EH3P100K10-NV-YD-H

GoodWe GW125-PCS-N-G10
GoodWe
GW125-PCS-N-G10
125 kW Hybrid
VS
Ginlong Solis S6-EH3P100K10-NV-YD-H
Ginlong Solis
S6-EH3P100K10-NV-YD-H
100 kW 97.2 % euro Hybrid
The verdict

GW125-PCS-N-G10 leads on the differences that matter

The largest is rated ac power: 25.00 kW apart. 9 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
9 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 18 parameters
Parameter GW125-PCS-N-G10 S6-EH3P100K10-NV-YD-H Difference
Rated AC power 125.00 kW 100.00 kW 25.00 kW apart
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max AC power 137.50 kW 100.00 kW 37.50 kW apart
Weight 80.0 kg 170.0 kg 90.0 kg lighter
Weight per kW 0.6 kg/kW 1.7 kg/kW 1.1 kg/kW lighter
Max AC current 198.5 A 151.9 A 46.6 A apart
Start voltage 670 V 180 V 490 V earlier start
Battery voltage 670-1000 300 - 950 V 670-1000 vs 300 - 950 V
Dimensions 266x600x900 mm 814x1174x400 mm 266x600x900 mm vs 814x1174x400 mm
02

Full specification

Parameter GW125-PCS-N-G10 S6-EH3P100K10-NV-YD-H Difference
AC output
Rated AC power 125.00 kW 100.00 kW 25.00 kW apart
Max AC power 137.50 kW 100.00 kW 37.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 198.5 A 151.9 A 46.6 A apart
PV input
Max PV power - 200.00 kW Not published by GoodWe
DC/AC ratio - 2.00 Not published by GoodWe
Max DC voltage 1000 V 1000 V Same
MPPT voltage range - 150-950 V Not published by GoodWe
Start voltage 670 V 180 V -490 V for S6-EH3P100K10-NV-YD-H
MPP trackers - 10 Not published by GoodWe
Strings per tracker - 2 Not published by GoodWe
Max input current per tracker - 42.0 A Not published by GoodWe
Efficiency
European efficiency - 97.2 % Not published by GoodWe
Max efficiency 98.6 % 97.6 % +1.0 pp for GW125-PCS-N-G10
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 670-1000 300 - 950 V 670-1000 vs 300 - 950 V
Max charge current - 200 A Not published by GoodWe
Backup power - - Neither datasheet publishes this
Physical
Weight 80.0 kg 170.0 kg -90.0 kg for GW125-PCS-N-G10
Weight per kW 0.6 kg/kW 1.7 kg/kW -1.1 kg/kW for GW125-PCS-N-G10
Dimensions 266x600x900 mm 814x1174x400 mm 266x600x900 mm vs 814x1174x400 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 80 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet Yes Yes Same
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
GoodWe GW125-PCS-N-G10 vs Ginlong Solis S6-EH3P125K10-NV-YD-H
8 differences, the largest is max efficiency
Same type, similar size
GoodWe
GoodWe GW125-PCS-N-G10 vs GoodWe GW125-PCS-N-G11
The same specification on paper
Same type, similar size
Growatt
GoodWe GW125-PCS-N-G10 vs Growatt WIT 100K-A-US / WIT 100K-AU-US
9 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH3P100K10-NV-YD-H vs Growatt WIT 100K-AU-US
10 differences, the largest is max efficiency
Same type, similar size
Growatt
Ginlong Solis S6-EH3P100K10-NV-YD-H vs Growatt WIT 100K-H-US / WIT 100K-HU-US
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EH3P100K10-NV-YD-H vs Growatt WIT 100K-A
6 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.