Skip to main content
Solis-80K-5G-PRO vs MAX 80KTL3 LV 10 of 20 identical Swap Change inverters

Solis-80K-5G-PRO vs Growatt MAX 80KTL3 LV

Solis-80K-5G-PRO
Ginlong Solis
Solis-80K-5G-PRO
80 kW 98.0 % euro Grid-tie
VS
Growatt MAX 80KTL3 LV
Growatt
MAX 80KTL3 LV
80 kW 98.5 % euro Grid-tie
The verdict

10 differences, and they point both ways

The largest is european efficiency: 0.5 pp more efficient. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
10 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 20 parameters
Parameter Solis-80K-5G-PRO MAX 80KTL3 LV Difference
European efficiency 98.0 % 98.5 % 0.5 pp more efficient
Max input current per tracker 40.0 A 26.0 A 14.0 A more headroom
Max AC power 88.00 kW 88.80 kW 0.80 kW apart
Weight 78.0 kg 86.0 kg 8.0 kg lighter
Max efficiency 98.5 % 99.0 % 0.5 pp more efficient
Max AC current 133.7 A 128.8 A 4.9 A apart
Start voltage 180 V 250 V 70 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 160-1000 V 200-1000 V 160-1000 V vs 200-1000 V
Dimensions 585x1065x363 mm 600x860x300 mm 585x1065x363 mm vs 600x860x300 mm
02

Full specification

Parameter Solis-80K-5G-PRO MAX 80KTL3 LV Difference
AC output
Rated AC power 80.00 kW 80.00 kW Same
Max AC power 88.00 kW 88.80 kW 0.80 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 133.7 A 128.8 A 4.9 A apart
PV input
Max PV power - 120.00 kW Not published by Ginlong Solis
DC/AC ratio - 1.50 Not published by Ginlong Solis
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 160-1000 V 200-1000 V 160-1000 V vs 200-1000 V
Start voltage 180 V 250 V -70 V for Solis-80K-5G-PRO
MPP trackers 6 - Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 26.0 A +14.0 A for Solis-80K-5G-PRO
Efficiency
European efficiency 98.0 % 98.5 % +0.5 pp for MAX 80KTL3 LV
Max efficiency 98.5 % 99.0 % +0.5 pp for MAX 80KTL3 LV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 78.0 kg 86.0 kg -8.0 kg for Solis-80K-5G-PRO
Weight per kW 1.0 kg/kW 1.1 kg/kW Effectively the same
Dimensions 585x1065x363 mm 600x860x300 mm 585x1065x363 mm vs 600x860x300 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Solis-80K-5G-PRO vs GoodWe GW80KBF-MT
11 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Solis-80K-5G-PRO vs GoodWe GW80KHV-MT
11 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Solis-80K-5G-PRO vs GoodWe GW80K-MT
11 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MAX 80KTL3 LV vs Ginlong Solis S6-GC3P80K07-LV-ND
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.