Solis-70K-HV-4G vs Deye SUN-70K-G03
VS
The verdict
SUN-70K-G03 leads on the differences that matter
The largest is max dc voltage: 100 V apart. 7 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
7
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 15 parameters
What actually differs
Parameter
Solis-70K-HV-4G
SUN-70K-G03
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max PV power
84.00 kW
91.00 kW
7.00 kW apart
DC/AC ratio
1.20
1.30
0.10 more oversizing headroom
Max AC current
92.6 A
116.7 A
24.1 A apart
Start voltage
200 V
250 V
50 V earlier start
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
MPPT voltage range
200-1000 V
200-850 V
200-1000 V vs 200-850 V
Dimensions
700x630x357 mm
568x838x324 mm
700x630x357 mm vs 568x838x324 mm
02
Full specification
Parameter
Solis-70K-HV-4G
SUN-70K-G03
Difference
AC output
Rated AC power
70.00 kW
70.00 kW
Same
Max AC power
77.00 kW
77.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
92.6 A
116.7 A
24.1 A apart
PV input
Max PV power
84.00 kW
91.00 kW
7.00 kW apart
DC/AC ratio
1.20
1.30
+0.10 for SUN-70K-G03
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
200-1000 V
200-850 V
200-1000 V vs 200-850 V
Start voltage
200 V
250 V
-50 V for Solis-70K-HV-4G
MPP trackers
4
-
Not published by Deye
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
40.0 A
Not published by Ginlong Solis
Efficiency
European efficiency
-
98.3 %
Not published by Ginlong Solis
Max efficiency
-
98.8 %
Not published by Ginlong Solis
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
81.0 kg
Not published by Ginlong Solis
Weight per kW
-
1.2 kg/kW
Not published by Ginlong Solis
Dimensions
700x630x357 mm
568x838x324 mm
700x630x357 mm vs 568x838x324 mm
Ingress protection
IP65
IP65
Same
Cooling
-
forced-air
Not published by Ginlong Solis
Noise
-
55 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
65 °C
+5 °C for SUN-70K-G03
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Solis-70K-HV-4G vs Growatt MAX 70KTL3 LV
6 differences, the largest is max ac power
Same type, similar size
Sofar Solar
Solis-70K-HV-4G vs SOFAR 70000TL-HV
9 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Solis-70K-HV-4G vs GoodWe GW70KHV-MT
2 differences, the largest is max ac current
Same type, similar size
Deye
Deye SUN-70K-G03 vs Deye SUN-70K-G
4 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.