Solis-50K-HV vs Sunny Tripower CORE1 STP 50-41 6 of 20 identical Swap Change inverters

Solis-50K-HV vs SMA Solar Sunny Tripower CORE1 STP 50-41

Solis-50K-HV
Ginlong Solis
Solis-50K-HV
50 kW 98.5 % euro Grid-tie
VS
SMA Solar Sunny Tripower CORE1 STP 50-41
SMA Solar
Sunny Tripower CORE1 STP 50-41
50 kW 97.8 % euro Grid-tie
The verdict

Solis-50K-HV leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 6 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
6 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 20 parameters
Parameter Solis-50K-HV Sunny Tripower CORE1 STP 50-41 Difference
European efficiency 98.5 % 97.8 % 0.7 pp more efficient
Max DC voltage 1100 V 1000 V 100 V apart
Max efficiency 99.0 % 98.1 % 0.9 pp more efficient
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Max PV power 60.00 kW 75.00 kW 15.00 kW apart
DC/AC ratio 1.20 1.50 0.30 more oversizing headroom
MPP trackers 4 6 2 trackers more
Weight 61.0 kg 84.0 kg 23.0 kg lighter
Weight per kW 1.2 kg/kW 1.7 kg/kW 0.5 kg/kW lighter
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 66.2 A 72.5 A 6.3 A apart
MPPT voltage range 200-1000 V 150-1000 V 200-1000 V vs 150-1000 V
Start voltage 200 V 188 V 12 V earlier start
Dimensions 700x630x357 mm 733x569x621 mm 700x630x357 mm vs 733x569x621 mm
02

Full specification

Parameter Solis-50K-HV Sunny Tripower CORE1 STP 50-41 Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 66.2 A 72.5 A 6.3 A apart
PV input
Max PV power 60.00 kW 75.00 kW 15.00 kW apart
DC/AC ratio 1.20 1.50 +0.30 for Sunny Tripower CORE1 STP 50-41
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 200-1000 V 150-1000 V 200-1000 V vs 150-1000 V
Start voltage 200 V 188 V -12 V for Sunny Tripower CORE1 STP 50-41
MPP trackers 4 6 +2 trackers for Sunny Tripower CORE1 STP 50-41
Strings per tracker - 2 Not published by Ginlong Solis
Max input current per tracker - 20.0 A Not published by Ginlong Solis
Efficiency
European efficiency 98.5 % 97.8 % +0.7 pp for Solis-50K-HV
Max efficiency 99.0 % 98.1 % +0.9 pp for Solis-50K-HV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 61.0 kg 84.0 kg -23.0 kg for Solis-50K-HV
Weight per kW 1.2 kg/kW 1.7 kg/kW -0.5 kg/kW for Solis-50K-HV
Dimensions 700x630x357 mm 733x569x621 mm 700x630x357 mm vs 733x569x621 mm
Ingress protection IP65 IP65 Same
Cooling - forced-air Not published by Ginlong Solis
Noise - 65 dB Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Ginlong Solis
Arc fault protection - Yes Not published by Ginlong Solis
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Solis-50K-HV vs Huawei SUN2000-50KTL-JPM0
6 differences, the largest is max ac power
Same type, similar size
Huawei
Solis-50K-HV vs Huawei SUN2000-50KTL-M0
6 differences, the largest is mpp trackers
Same type, similar size
Growatt
Solis-50K-HV vs Growatt MAX 50KTL3 LV
9 differences, the largest is max ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.