Ginlong Solis S6-GR3P-9K02-NV-ND vs SolarEdge SE9KUS (208V three-phase)
VS
The verdict
S6-GR3P-9K02-NV-ND leads on the differences that matter
The largest is max dc voltage: 500 V apart. 4 of 13 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
4
of 13 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 13 parameters
What actually differs
Parameter
S6-GR3P-9K02-NV-ND
SolarEdge SE9KUS (208V three-phase)
Difference
Max DC voltage
1100 V
600 V
500 V apart
Max PV power
13.50 kW
12.15 kW
1.35 kW apart
Weight
15.4 kg
33.2 kg
17.8 kg lighter
Weight per kW
1.7 kg/kW
3.7 kg/kW
2.0 kg/kW lighter
DC/AC ratio
1.50
1.35
0.15 more oversizing headroom
Max AC current
13.7 A
25.0 A
11.3 A apart
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
Dimensions
410x355x179 mm
540x315x260 mm
410x355x179 mm vs 540x315x260 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
S6-GR3P-9K02-NV-ND
SolarEdge SE9KUS (208V three-phase)
Difference
AC output
Rated AC power
9.00 kW
9.00 kW
Same
Max AC power
9.00 kW
9.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
208 V
Not published by Ginlong Solis
Max AC current
13.7 A
25.0 A
11.3 A apart
PV input
Max PV power
13.50 kW
12.15 kW
1.35 kW apart
DC/AC ratio
1.50
1.35
+0.15 for S6-GR3P-9K02-NV-ND
Max DC voltage
1100 V
600 V
500 V apart
MPPT voltage range
160-1000 V
-
Not published by SolarEdge
Start voltage
160 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
21.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.9 %
-
Not published by SolarEdge
Max efficiency
98.5 %
-
Not published by SolarEdge
CEC efficiency
-
96.5 %
Not published by Ginlong Solis
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.4 kg
33.2 kg
-17.8 kg for S6-GR3P-9K02-NV-ND
Weight per kW
1.7 kg/kW
3.7 kg/kW
-2.0 kg/kW for S6-GR3P-9K02-NV-ND
Dimensions
410x355x179 mm
540x315x260 mm
410x355x179 mm vs 540x315x260 mm
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
Cooling
natural
forced-air
natural vs forced-air
Noise
30 dB
-
Not published by SolarEdge
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GR3P-9K02-NV-ND vs Growatt MOD 9000TL3-X
6 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR3P-9K02-NV-ND vs Solis-3P9K-4G
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-GR3P-9K02-NV-ND vs Growatt MIN 9000TL-X
11 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.