SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
9 kW
97.5 % euro
Grid-tie
The verdict
S6-GR3P-9K02-NV-ND leads on the differences that matter
The largest is max dc voltage: 200 V apart. 7 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
7
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 16 parameters
What actually differs
Parameter
S6-GR3P-9K02-NV-ND
SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
Difference
Max DC voltage
1100 V
900 V
200 V apart
European efficiency
97.9 %
97.5 %
0.4 pp more efficient
Noise
30 dB
40 dB
10 dB quieter
Max efficiency
98.5 %
98.0 %
0.5 pp more efficient
Weight
15.4 kg
16.4 kg
1.0 kg lighter
Ingress protection
IP66
IP65
IP66 vs IP65
Max AC current
13.7 A
14.5 A
0.8 A apart
Dimensions
410x355x179 mm
540x315x191 mm
410x355x179 mm vs 540x315x191 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
S6-GR3P-9K02-NV-ND
SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
Difference
AC output
Rated AC power
9.00 kW
9.00 kW
Same
Max AC power
9.00 kW
9.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
400 V
Not published by Ginlong Solis
Max AC current
13.7 A
14.5 A
0.8 A apart
PV input
Max PV power
13.50 kW
13.50 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1100 V
900 V
200 V apart
MPPT voltage range
160-1000 V
-
Not published by SolarEdge
Start voltage
160 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
21.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.9 %
97.5 %
+0.4 pp for S6-GR3P-9K02-NV-ND
Max efficiency
98.5 %
98.0 %
+0.5 pp for S6-GR3P-9K02-NV-ND
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.4 kg
16.4 kg
-1.0 kg for S6-GR3P-9K02-NV-ND
Weight per kW
1.7 kg/kW
1.8 kg/kW
Effectively the same
Dimensions
410x355x179 mm
540x315x191 mm
410x355x179 mm vs 540x315x191 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
30 dB
40 dB
-10 dB for S6-GR3P-9K02-NV-ND
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GR3P-9K02-NV-ND vs Growatt MOD 9000TL3-X
6 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR3P-9K02-NV-ND vs Solis-3P9K-4G
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-GR3P-9K02-NV-ND vs Growatt MIN 9000TL-X
11 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.