Skip to main content
S6-GR3P-5K02-NV-ND vs IGrid SMP 5KW 2 of 9 identical Swap Change inverters

Ginlong Solis S6-GR3P-5K02-NV-ND vs Easun Power IGrid SMP 5KW

Ginlong Solis S6-GR3P-5K02-NV-ND
Ginlong Solis
S6-GR3P-5K02-NV-ND
5 kW 97.7 % euro Grid-tie
VS
Easun Power
IGrid SMP 5KW
5 kW Grid-tie
The verdict

7 differences, and they point both ways

The largest is max pv power: 2.50 kW apart. 2 of 9 comparable parameters are identical, with 23 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
2 of 9 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 9 parameters
Parameter S6-GR3P-5K02-NV-ND IGrid SMP 5KW Difference
Max PV power 7.50 kW 5.00 kW 2.50 kW apart
DC/AC ratio 1.50 1.00 0.50 more oversizing headroom
Weight 14.7 kg 12.0 kg 2.7 kg lighter
Noise 30 dB 60 dB 30 dB quieter
Weight per kW 2.9 kg/kW 2.4 kg/kW 0.5 kg/kW lighter
Dimensions 410x355x179 mm 456x303x147 mm 410x355x179 mm vs 456x303x147 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter S6-GR3P-5K02-NV-ND IGrid SMP 5KW Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.00 kW 5.00 kW Same
Grid connection 3-phase - Not published by Easun Power
Nominal AC voltage - - Neither datasheet publishes this
Max AC current 7.6 A - Not published by Easun Power
PV input
Max PV power 7.50 kW 5.00 kW 2.50 kW apart
DC/AC ratio 1.50 1.00 +0.50 for S6-GR3P-5K02-NV-ND
Max DC voltage 1100 V - Not published by Easun Power
MPPT voltage range 160-1000 V - Not published by Easun Power
Start voltage 160 V - Not published by Easun Power
MPP trackers 2 - Not published by Easun Power
Strings per tracker 1 - Not published by Easun Power
Max input current per tracker 21.0 A - Not published by Easun Power
Efficiency
European efficiency 97.7 % - Not published by Easun Power
Max efficiency 98.3 % - Not published by Easun Power
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.7 kg 12.0 kg -2.7 kg for IGrid SMP 5KW
Weight per kW 2.9 kg/kW 2.4 kg/kW -0.5 kg/kW for IGrid SMP 5KW
Dimensions 410x355x179 mm 456x303x147 mm 410x355x179 mm vs 456x303x147 mm
Ingress protection IP66 - Not published by Easun Power
Cooling natural forced-air natural vs forced-air
Noise 30 dB 60 dB -30 dB for S6-GR3P-5K02-NV-ND
Max operating temperature 60 °C - Not published by Easun Power
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Easun Power
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Ginlong Solis S6-GR3P-5K02-NV-ND vs SolarEdge SE5000H (HD‑Wave, single phase)
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Ginlong Solis S6-GR3P-5K02-NV-ND vs SolarEdge EV Charging Single Phase Inverter SE5000H (aka H5000SE / SE5000H)
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR3P-5K02-NV-ND vs Solis-3P5K-4G
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.