Ginlong Solis S6-GR3P-4K02-NV-ND vs GoodWe GW4K-DT
VS
The verdict
6 differences, none of them an advantage
The largest is max dc voltage: 100 V apart. 11 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
11
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 17 parameters
What actually differs
Parameter
S6-GR3P-4K02-NV-ND
GW4K-DT
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max AC power
4.00 kW
4.40 kW
0.40 kW apart
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
160-1000 V
180-850 V
160-1000 V vs 180-850 V
Dimensions
410x355x179 mm
433x354x147 mm
410x355x179 mm vs 433x354x147 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
S6-GR3P-4K02-NV-ND
GW4K-DT
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.00 kW
4.40 kW
0.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
400 V
Not published by Ginlong Solis
Max AC current
6.1 A
6.4 A
Effectively the same
PV input
Max PV power
6.00 kW
-
Not published by GoodWe
DC/AC ratio
1.50
-
Not published by GoodWe
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
160-1000 V
180-850 V
160-1000 V vs 180-850 V
Start voltage
160 V
160 V
Same
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by GoodWe
Max input current per tracker
21.0 A
-
Not published by GoodWe
Efficiency
European efficiency
97.7 %
97.6 %
Effectively the same
Max efficiency
98.3 %
98.2 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
14.7 kg
15.0 kg
Effectively the same
Weight per kW
3.7 kg/kW
3.8 kg/kW
Effectively the same
Dimensions
410x355x179 mm
433x354x147 mm
410x355x179 mm vs 433x354x147 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
30 dB
-
Not published by GoodWe
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Ginlong Solis S6-GR3P-4K02-NV-ND vs SolarEdge EV Charging Single Phase Inverter SE4000H (aka H4000SE / SE4000H)
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Ginlong Solis S6-GR3P-4K02-NV-ND vs SolarEdge SE4000H (HD‑Wave, single phase)
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR3P-4K02-NV-ND vs Solis-3P4K-4G
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.