Ginlong Solis S6-GR1P9K03-NV-ND vs Growatt MIN 9000TL-X
VS
The verdict
MIN 9000TL-X leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 11 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
11
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 22 parameters
What actually differs
Parameter
S6-GR1P9K03-NV-ND
MIN 9000TL-X
Difference
European efficiency
97.1 %
97.6 %
0.5 pp more efficient
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
20.0 A
27.0 A
7.0 A more headroom
Weight
16.1 kg
18.2 kg
2.1 kg lighter
Max AC current
40.9 A
43.0 A
2.1 A apart
Start voltage
60 V
100 V
40 V earlier start
Weight per kW
1.8 kg/kW
2.0 kg/kW
0.2 kg/kW lighter
Nominal AC voltage
230 V
240 V
10 V apart
MPPT voltage range
50-500 V
60-550 V
50-500 V vs 60-550 V
Dimensions
510x335x220 mm
387x425x180 mm
510x335x220 mm vs 387x425x180 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
S6-GR1P9K03-NV-ND
MIN 9000TL-X
Difference
AC output
Rated AC power
9.00 kW
9.00 kW
Same
Max AC power
9.00 kW
9.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
40.9 A
43.0 A
2.1 A apart
PV input
Max PV power
13.50 kW
13.50 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
50-500 V
60-550 V
50-500 V vs 60-550 V
Start voltage
60 V
100 V
-40 V for S6-GR1P9K03-NV-ND
MPP trackers
3
-
Not published by Growatt
Strings per tracker
1
-
Not published by Growatt
Max input current per tracker
20.0 A
27.0 A
+7.0 A for MIN 9000TL-X
Efficiency
European efficiency
97.1 %
97.6 %
+0.5 pp for MIN 9000TL-X
Max efficiency
98.0 %
98.1 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
16.1 kg
18.2 kg
-2.1 kg for S6-GR1P9K03-NV-ND
Weight per kW
1.8 kg/kW
2.0 kg/kW
-0.2 kg/kW for S6-GR1P9K03-NV-ND
Dimensions
510x335x220 mm
387x425x180 mm
510x335x220 mm vs 387x425x180 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
natural
forced-air vs natural
Noise
40 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GR1P9K03-NV-ND vs Growatt MOD 9000TL3-X
14 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P9K03-NV-ND vs Ginlong Solis S6-GR3P-9K02-NV-ND
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P9K03-NV-ND vs Solis-3P9K-4G
16 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MIN 9000TL-X vs SolarEdge SE9K-RWZZZBEN4 (per inverter; bundle is 2×SE9K, marketed as SE18K-BUNDLE*)
9 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.