Skip to main content
S6-GR1P8K03-NV-ND vs MOD 8000TL3-X 9 of 23 identical Swap Change inverters

Ginlong Solis S6-GR1P8K03-NV-ND vs Growatt MOD 8000TL3-X

Ginlong Solis S6-GR1P8K03-NV-ND
Ginlong Solis
S6-GR1P8K03-NV-ND
8 kW 97.1 % euro Grid-tie
VS
Growatt MOD 8000TL3-X
Growatt
MOD 8000TL3-X
8 kW 98.1 % euro Grid-tie
The verdict

MOD 8000TL3-X leads on the differences that matter

The largest is european efficiency: 1.0 pp more efficient. 9 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
9 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 23 parameters
Parameter S6-GR1P8K03-NV-ND MOD 8000TL3-X Difference
European efficiency 97.1 % 98.1 % 1.0 pp more efficient
Max DC voltage 550 V 1100 V 550 V apart
Max input current per tracker 20.0 A 13.0 A 7.0 A more headroom
Max efficiency 98.0 % 98.6 % 0.6 pp more efficient
Weight 16.1 kg 14.0 kg 2.1 kg lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 36.4 A 13.3 A 23.1 A apart
Start voltage 60 V 160 V 100 V earlier start
MPP trackers 3 2 1 tracker more
Weight per kW 2.0 kg/kW 1.8 kg/kW 0.3 kg/kW lighter
MPPT voltage range 50-500 V 140-1000 V 50-500 V vs 140-1000 V
Dimensions 510x335x220 mm 387x425x178 mm 510x335x220 mm vs 387x425x178 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter S6-GR1P8K03-NV-ND MOD 8000TL3-X Difference
AC output
Rated AC power 8.00 kW 8.00 kW Same
Max AC power 8.00 kW 8.00 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 36.4 A 13.3 A 23.1 A apart
PV input
Max PV power 12.00 kW 12.00 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 550 V 1100 V 550 V apart
MPPT voltage range 50-500 V 140-1000 V 50-500 V vs 140-1000 V
Start voltage 60 V 160 V -100 V for S6-GR1P8K03-NV-ND
MPP trackers 3 2 +1 trackers for S6-GR1P8K03-NV-ND
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 13.0 A +7.0 A for S6-GR1P8K03-NV-ND
Efficiency
European efficiency 97.1 % 98.1 % +1.0 pp for MOD 8000TL3-X
Max efficiency 98.0 % 98.6 % +0.6 pp for MOD 8000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 16.1 kg 14.0 kg -2.1 kg for MOD 8000TL3-X
Weight per kW 2.0 kg/kW 1.8 kg/kW -0.3 kg/kW for MOD 8000TL3-X
Dimensions 510x335x220 mm 387x425x178 mm 510x335x220 mm vs 387x425x178 mm
Ingress protection IP66 IP66 Same
Cooling forced-air natural forced-air vs natural
Noise 40 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Ginlong Solis
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-GR1P8K03-NV-ND vs Growatt MOD 8KTL3-X2(Pro)
12 differences, the largest is european efficiency
Same type, similar size
Sungrow
Ginlong Solis S6-GR1P8K03-NV-ND vs Sungrow SG8.0RT-20
13 differences, the largest is european efficiency
Same type, similar size
GoodWe
Ginlong Solis S6-GR1P8K03-NV-ND vs GoodWe GW8000-DT
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MOD 8000TL3-X vs Ginlong Solis S6-GR3P-8K02-NV-ND
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.