MIN 4600TL-X2 (Pro) leads on the differences that matter
The largest is max dc voltage: 50 V apart. 11 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
11
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 22 parameters
What actually differs
Parameter
S6-GR1P4.6K
MIN 4600TL-X2 (Pro)
Difference
Max DC voltage
600 V
550 V
50 V apart
Max input current per tracker
14.0 A
18.0 A
4.0 A more headroom
Max efficiency
97.7 %
98.4 %
0.7 pp more efficient
European efficiency
97.1 %
97.5 %
0.4 pp more efficient
Max AC power
5.00 kW
4.60 kW
0.40 kW apart
Weight
12.0 kg
10.8 kg
1.2 kg lighter
Max AC current
23.8 A
20.9 A
2.9 A apart
Weight per kW
2.6 kg/kW
2.3 kg/kW
0.3 kg/kW lighter
MPPT voltage range
50-520 V
40-550 V
50-520 V vs 40-550 V
Start voltage
60 V
50 V
10 V earlier start
Dimensions
543x310x160 mm
350x375x158 mm
543x310x160 mm vs 350x375x158 mm
02
Full specification
Parameter
S6-GR1P4.6K
MIN 4600TL-X2 (Pro)
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.00 kW
4.60 kW
0.40 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
23.8 A
20.9 A
2.9 A apart
PV input
Max PV power
6.90 kW
6.90 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
600 V
550 V
50 V apart
MPPT voltage range
50-520 V
40-550 V
50-520 V vs 40-550 V
Start voltage
60 V
50 V
-10 V for MIN 4600TL-X2 (Pro)
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
14.0 A
18.0 A
+4.0 A for MIN 4600TL-X2 (Pro)
Efficiency
European efficiency
97.1 %
97.5 %
+0.4 pp for MIN 4600TL-X2 (Pro)
Max efficiency
97.7 %
98.4 %
+0.7 pp for MIN 4600TL-X2 (Pro)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.0 kg
10.8 kg
-1.2 kg for MIN 4600TL-X2 (Pro)
Weight per kW
2.6 kg/kW
2.3 kg/kW
-0.3 kg/kW for MIN 4600TL-X2 (Pro)
Dimensions
543x310x160 mm
350x375x158 mm
543x310x160 mm vs 350x375x158 mm
Ingress protection
IP66
IP66
Same
Cooling
natural
natural
Same
Noise
20 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Ginlong Solis S6-GR1P4.6K vs GoodWe GW4600-SS
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-GR1P4.6K vs Growatt MIN 4600TL-X
14 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Ginlong Solis S6-GR1P4.6K vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.