Skip to main content
S6-GR1P4.6K vs MIN 4600TL-X2 (Pro) 11 of 22 identical Swap Change inverters

Ginlong Solis S6-GR1P4.6K vs Growatt MIN 4600TL-X2 (Pro)

Ginlong Solis S6-GR1P4.6K
Ginlong Solis
S6-GR1P4.6K
4.6 kW 97.1 % euro Grid-tie
VS
Growatt MIN 4600TL-X2 (Pro)
Growatt
MIN 4600TL-X2 (Pro)
4.6 kW 97.5 % euro Grid-tie
The verdict

MIN 4600TL-X2 (Pro) leads on the differences that matter

The largest is max dc voltage: 50 V apart. 11 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
11 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 22 parameters
Parameter S6-GR1P4.6K MIN 4600TL-X2 (Pro) Difference
Max DC voltage 600 V 550 V 50 V apart
Max input current per tracker 14.0 A 18.0 A 4.0 A more headroom
Max efficiency 97.7 % 98.4 % 0.7 pp more efficient
European efficiency 97.1 % 97.5 % 0.4 pp more efficient
Max AC power 5.00 kW 4.60 kW 0.40 kW apart
Weight 12.0 kg 10.8 kg 1.2 kg lighter
Max AC current 23.8 A 20.9 A 2.9 A apart
Weight per kW 2.6 kg/kW 2.3 kg/kW 0.3 kg/kW lighter
MPPT voltage range 50-520 V 40-550 V 50-520 V vs 40-550 V
Start voltage 60 V 50 V 10 V earlier start
Dimensions 543x310x160 mm 350x375x158 mm 543x310x160 mm vs 350x375x158 mm
02

Full specification

Parameter S6-GR1P4.6K MIN 4600TL-X2 (Pro) Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 5.00 kW 4.60 kW 0.40 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 23.8 A 20.9 A 2.9 A apart
PV input
Max PV power 6.90 kW 6.90 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 600 V 550 V 50 V apart
MPPT voltage range 50-520 V 40-550 V 50-520 V vs 40-550 V
Start voltage 60 V 50 V -10 V for MIN 4600TL-X2 (Pro)
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 14.0 A 18.0 A +4.0 A for MIN 4600TL-X2 (Pro)
Efficiency
European efficiency 97.1 % 97.5 % +0.4 pp for MIN 4600TL-X2 (Pro)
Max efficiency 97.7 % 98.4 % +0.7 pp for MIN 4600TL-X2 (Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 12.0 kg 10.8 kg -1.2 kg for MIN 4600TL-X2 (Pro)
Weight per kW 2.6 kg/kW 2.3 kg/kW -0.3 kg/kW for MIN 4600TL-X2 (Pro)
Dimensions 543x310x160 mm 350x375x158 mm 543x310x160 mm vs 350x375x158 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise 20 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Ginlong Solis S6-GR1P4.6K vs GoodWe GW4600-SS
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-GR1P4.6K vs Growatt MIN 4600TL-X
14 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Ginlong Solis S6-GR1P4.6K vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.