Ginlong Solis S6-GR1P4.6K-S vs GoodWe GW4600-SS
VS
The verdict
S6-GR1P4.6K-S leads on the differences that matter
The largest is max dc voltage: 50 V apart. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
7
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 21 parameters
What actually differs
Parameter
S6-GR1P4.6K-S
GW4600-SS
Difference
Max DC voltage
550 V
500 V
50 V apart
Max AC power
4.60 kW
5.10 kW
0.50 kW apart
Max PV power
6.90 kW
5.40 kW
1.50 kW apart
DC/AC ratio
1.50
1.17
0.33 more oversizing headroom
Weight
9.0 kg
18.0 kg
9.0 kg lighter
Weight per kW
2.0 kg/kW
3.9 kg/kW
2.0 kg/kW lighter
European efficiency
97.1 %
97.4 %
0.3 pp more efficient
Noise
20 dB
25 dB
5 dB quieter
Max AC current
20.9 A
23.0 A
2.1 A apart
Start voltage
60 V
125 V
65 V earlier start
MPP trackers
2
1
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
50-550 V
125-450 V
50-550 V vs 125-450 V
Dimensions
371x330x161 mm
390x397x180 mm
371x330x161 mm vs 390x397x180 mm
02
Full specification
Parameter
S6-GR1P4.6K-S
GW4600-SS
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
5.10 kW
0.50 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.9 A
23.0 A
2.1 A apart
PV input
Max PV power
6.90 kW
5.40 kW
1.50 kW apart
DC/AC ratio
1.50
1.17
+0.33 for S6-GR1P4.6K-S
Max DC voltage
550 V
500 V
50 V apart
MPPT voltage range
50-550 V
125-450 V
50-550 V vs 125-450 V
Start voltage
60 V
125 V
-65 V for S6-GR1P4.6K-S
MPP trackers
2
1
+1 trackers for S6-GR1P4.6K-S
Strings per tracker
1
-
Not published by GoodWe
Max input current per tracker
16.0 A
-
Not published by GoodWe
Efficiency
European efficiency
97.1 %
97.4 %
+0.3 pp for GW4600-SS
Max efficiency
97.7 %
97.8 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
9.0 kg
18.0 kg
-9.0 kg for S6-GR1P4.6K-S
Weight per kW
2.0 kg/kW
3.9 kg/kW
-2.0 kg/kW for S6-GR1P4.6K-S
Dimensions
371x330x161 mm
390x397x180 mm
371x330x161 mm vs 390x397x180 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
20 dB
25 dB
-5 dB for S6-GR1P4.6K-S
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GR1P4.6K-S vs Growatt MIN 4600TL-X2 (Pro)
8 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-GR1P4.6K-S vs Growatt MIN 4600TL-X
13 differences, the largest is max input current per tracker
Same type, similar size
Fronius International
Ginlong Solis S6-GR1P4.6K-S vs Fronius Primo 5.0-1 AUS
16 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
GoodWe GW4600-SS vs Ginlong Solis S6-GR1P4.6K
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.