Skip to main content
S6-GR1P3.6K-S vs IGrid SV IV 3.6KW 2 of 10 identical Swap Change inverters

Ginlong Solis S6-GR1P3.6K-S vs Easun Power IGrid SV IV 3.6KW

Ginlong Solis S6-GR1P3.6K-S
Ginlong Solis
S6-GR1P3.6K-S
3.6 kW 97.1 % euro Grid-tie
VS
Easun Power
IGrid SV IV 3.6KW
3.6 kW Grid-tie
The verdict

S6-GR1P3.6K-S leads on the differences that matter

The largest is max efficiency: 1.6 pp more efficient. 2 of 10 comparable parameters are identical, with 22 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
2 of 10 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 10 parameters
Parameter S6-GR1P3.6K-S IGrid SV IV 3.6KW Difference
Max efficiency 97.6 % 96.0 % 1.6 pp more efficient
Max PV power 5.40 kW 5.00 kW 0.40 kW apart
Weight 8.9 kg 11.0 kg 2.1 kg lighter
Noise 20 dB 60 dB 40 dB quieter
Weight per kW 2.5 kg/kW 3.1 kg/kW 0.6 kg/kW lighter
DC/AC ratio 1.50 1.39 0.11 more oversizing headroom
Dimensions 371x330x161 mm 468x295x468 mm 371x330x161 mm vs 468x295x468 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter S6-GR1P3.6K-S IGrid SV IV 3.6KW Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.60 kW 3.60 kW Same
Grid connection Single-phase - Not published by Easun Power
Nominal AC voltage 230 V - Not published by Easun Power
Max AC current 16.0 A - Not published by Easun Power
PV input
Max PV power 5.40 kW 5.00 kW 0.40 kW apart
DC/AC ratio 1.50 1.39 +0.11 for S6-GR1P3.6K-S
Max DC voltage 550 V - Not published by Easun Power
MPPT voltage range 50-550 V - Not published by Easun Power
Start voltage 60 V - Not published by Easun Power
MPP trackers 2 - Not published by Easun Power
Strings per tracker 1 - Not published by Easun Power
Max input current per tracker 16.0 A - Not published by Easun Power
Efficiency
European efficiency 97.1 % - Not published by Easun Power
Max efficiency 97.6 % 96.0 % +1.6 pp for S6-GR1P3.6K-S
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 8.9 kg 11.0 kg -2.1 kg for S6-GR1P3.6K-S
Weight per kW 2.5 kg/kW 3.1 kg/kW -0.6 kg/kW for S6-GR1P3.6K-S
Dimensions 371x330x161 mm 468x295x468 mm 371x330x161 mm vs 468x295x468 mm
Ingress protection IP66 - Not published by Easun Power
Cooling natural forced-air natural vs forced-air
Noise 20 dB 60 dB -40 dB for S6-GR1P3.6K-S
Max operating temperature 60 °C - Not published by Easun Power
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Easun Power
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Sofar Solar
Ginlong Solis S6-GR1P3.6K-S vs SOFAR 3.6KTLM-G3
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-GR1P3.6K-S vs Growatt MIN 3600TL-X
13 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GR1P3.6K-S vs Ginlong Solis S6-GR1P3.6K-M
9 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.