Ginlong Solis S6-GC3P23K03-LV-ND vs GoodWe GW23K-SDT-CN-G40
VS
The verdict
GW23K-SDT-CN-G40 leads on the differences that matter
The largest is max input current per tracker: 19.0 A more headroom. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
8
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 19 parameters
What actually differs
Parameter
S6-GC3P23K03-LV-ND
GW23K-SDT-CN-G40
Difference
Max input current per tracker
40.0 A
21.0 A
19.0 A more headroom
Max efficiency
97.8 %
98.7 %
0.9 pp more efficient
Max AC power
23.00 kW
25.30 kW
2.30 kW apart
Weight
32.6 kg
17.0 kg
15.6 kg lighter
Noise
60 dB
45 dB
15 dB quieter
Weight per kW
1.4 kg/kW
0.7 kg/kW
0.7 kg/kW lighter
Nominal AC voltage
230 V
380 V
150 V apart
Max AC current
60.4 A
38.4 A
22.0 A apart
MPPT voltage range
180-1000 V
140-1000 V
180-1000 V vs 140-1000 V
Start voltage
180 V
160 V
20 V earlier start
Dimensions
672x515x288 mm
413x530x211 mm
672x515x288 mm vs 413x530x211 mm
02
Full specification
Parameter
S6-GC3P23K03-LV-ND
GW23K-SDT-CN-G40
Difference
AC output
Rated AC power
23.00 kW
23.00 kW
Same
Max AC power
23.00 kW
25.30 kW
2.30 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
380 V
150 V apart
Max AC current
60.4 A
38.4 A
22.0 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
140-1000 V
180-1000 V vs 140-1000 V
Start voltage
180 V
160 V
-20 V for GW23K-SDT-CN-G40
MPP trackers
-
2
Not published by Ginlong Solis
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
21.0 A
+19.0 A for S6-GC3P23K03-LV-ND
Efficiency
European efficiency
97.3 %
-
Not published by GoodWe
Max efficiency
97.8 %
98.7 %
+0.9 pp for GW23K-SDT-CN-G40
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
32.6 kg
17.0 kg
-15.6 kg for GW23K-SDT-CN-G40
Weight per kW
1.4 kg/kW
0.7 kg/kW
-0.7 kg/kW for GW23K-SDT-CN-G40
Dimensions
672x515x288 mm
413x530x211 mm
672x515x288 mm vs 413x530x211 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
60 dB
45 dB
-15 dB for GW23K-SDT-CN-G40
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Sungrow
Ginlong Solis S6-GC3P23K03-LV-ND vs Sungrow SG23T-P2-CN
10 differences, the largest is european efficiency
Same type, similar size
Sofar Solar
Ginlong Solis S6-GC3P23K03-LV-ND vs SOFAR 23KTLX-G3P
7 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GC3P23K03-LV-ND vs Ginlong Solis S5-GC23K-LV
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.