Ginlong Solis S6-EH3P5K-H-EU vs SolarEdge SE5000H
VS
The verdict
SE5000H leads on the differences that matter
The largest is max dc voltage: 520 V apart. 7 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
7
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 16 parameters
What actually differs
Parameter
S6-EH3P5K-H-EU
SE5000H
Difference
Max DC voltage
1000 V
480 V
520 V apart
Max efficiency
96.5 %
99.2 %
2.7 pp more efficient
Weight
27.6 kg
12.0 kg
15.6 kg lighter
Weight per kW
5.5 kg/kW
2.4 kg/kW
3.1 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
7.6 A
23.0 A
15.4 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
500x600x210 mm
459x370x154 mm
500x600x210 mm vs 459x370x154 mm
02
Full specification
Parameter
S6-EH3P5K-H-EU
SE5000H
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
7.6 A
23.0 A
15.4 A apart
PV input
Max PV power
10.00 kW
10.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
480 V
520 V apart
MPPT voltage range
200-850 V
-
Not published by SolarEdge
Start voltage
160 V
-
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
16.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
-
99.0 %
Not published by Ginlong Solis
Max efficiency
96.5 %
99.2 %
+2.7 pp for SE5000H
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
120-600 V (note: supports max battery voltage up to 700 V)
-
Not published by SolarEdge
Max charge current
50 A
-
Not published by SolarEdge
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
27.6 kg
12.0 kg
-15.6 kg for SE5000H
Weight per kW
5.5 kg/kW
2.4 kg/kW
-3.1 kg/kW for SE5000H
Dimensions
500x600x210 mm
459x370x154 mm
500x600x210 mm vs 459x370x154 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
47 dB
-
Not published by SolarEdge
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Ginlong Solis S6-EH3P5K-H-EU vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
10 differences, the largest is max dc voltage
Same type, similar size
Huawei
Ginlong Solis S6-EH3P5K-H-EU vs Huawei SUN2000L-5KTL
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EH3P5K-H-EU vs Growatt MOD 5000TL3-HU
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
SolarEdge SE5000H vs Huawei SUN2000-5KTL-L1
7 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.