Skip to main content
S6-EH3P30K-H-LV vs WIT 30K-XHU 12 of 24 identical Swap Change inverters

Ginlong Solis S6-EH3P30K-H-LV vs Growatt WIT 30K-XHU

Ginlong Solis S6-EH3P30K-H-LV
Ginlong Solis
S6-EH3P30K-H-LV
30 kW 95.5 % euro Hybrid
VS
Growatt WIT 30K-XHU
Growatt
WIT 30K-XHU
30 kW Hybrid
The verdict

WIT 30K-XHU leads on the differences that matter

The largest is max dc voltage: 100 V apart. 12 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
12 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 24 parameters
Parameter S6-EH3P30K-H-LV WIT 30K-XHU Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max efficiency 96.3 % 98.1 % 1.8 pp more efficient
Max charge current 140 A 165 A 25 A faster charging
Weight 73.0 kg 90.0 kg 17.0 kg lighter
Weight per kW 2.4 kg/kW 3.0 kg/kW 0.6 kg/kW lighter
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 78.7 A 50.0 A 28.7 A apart
MPP trackers 3 4 1 tracker more
MPPT voltage range 150-850 V 180-1000 V 150-850 V vs 180-1000 V
Battery voltage 150-800 V 200-900V 150-800 V vs 200-900V
Start voltage 180 V 195 V 15 V earlier start
Dimensions 880x530x290 mm 585x920x320 mm 880x530x290 mm vs 585x920x320 mm
02

Full specification

Parameter S6-EH3P30K-H-LV WIT 30K-XHU Difference
AC output
Rated AC power 30.00 kW 30.00 kW Same
Max AC power 30.00 kW 30.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 78.7 A 50.0 A 28.7 A apart
PV input
Max PV power 60.00 kW 60.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 150-850 V 180-1000 V 150-850 V vs 180-1000 V
Start voltage 180 V 195 V -15 V for S6-EH3P30K-H-LV
MPP trackers 3 4 +1 trackers for WIT 30K-XHU
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 40.0 A Same
Efficiency
European efficiency 95.5 % - Not published by Growatt
Max efficiency 96.3 % 98.1 % +1.8 pp for WIT 30K-XHU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 150-800 V 200-900V 150-800 V vs 200-900V
Max charge current 140 A 165 A +25 A for WIT 30K-XHU
Backup power 30.0 kW - Not published by Growatt
Physical
Weight 73.0 kg 90.0 kg -17.0 kg for S6-EH3P30K-H-LV
Weight per kW 2.4 kg/kW 3.0 kg/kW -0.6 kg/kW for S6-EH3P30K-H-LV
Dimensions 880x530x290 mm 585x920x320 mm 880x530x290 mm vs 585x920x320 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - 55 dB Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Ginlong Solis
Ethernet Yes Yes Same
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Ginlong Solis S6-EH3P30K-H-LV vs Ginlong Solis S6-EH3P30K-H
4 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis S6-EH3P30K-H-LV vs Growatt MID 30K-HU
11 differences, the largest is european efficiency
Same type, similar size
Deye
Ginlong Solis S6-EH3P30K-H-LV vs Deye SUN-30K-SG01HP3-EU-BM3
14 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.