Ginlong Solis S6-EH1P3K-L-PLUS vs Growatt SPM 3000TL-HU
VS
The verdict
18 differences, and they point both ways
The largest is european efficiency: 1.5 pp more efficient. 9 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 18 differencesHow alike are they
9
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
18 of 27 parameters
What actually differs
Parameter
S6-EH1P3K-L-PLUS
SPM 3000TL-HU
Difference
European efficiency
96.1 %
97.6 %
1.5 pp more efficient
Max DC voltage
500 V
600 V
100 V apart
Max efficiency
96.2 %
98.1 %
1.9 pp more efficient
Max charge current
210 A
140 A
70 A faster charging
Weight
23.0 kg
26.0 kg
3.0 kg lighter
Weight per kW
7.7 kg/kW
8.7 kg/kW
1.0 kg/kW lighter
Noise
65 dB
30 dB
35 dB quieter
Max input current per tracker
21.0 A
22.0 A
1.0 A more headroom
Max PV power
4.80 kW
4.50 kW
0.30 kW apart
DC/AC ratio
1.60
1.50
0.10 more oversizing headroom
Start voltage
90 V
130 V
40 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
90-435 V
150-550 V
90-435 V vs 150-550 V
Battery voltage
40-60 V
40-60V
40-60 V vs 40-60V
Max AC current
13.7 A
13.1 A
0.6 A apart
Strings per tracker
2
1
1 string apart
Dimensions
560x335x253 mm
330x580x230 mm
560x335x253 mm vs 330x580x230 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
S6-EH1P3K-L-PLUS
SPM 3000TL-HU
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
13.7 A
13.1 A
0.6 A apart
PV input
Max PV power
4.80 kW
4.50 kW
0.30 kW apart
DC/AC ratio
1.60
1.50
+0.10 for S6-EH1P3K-L-PLUS
Max DC voltage
500 V
600 V
100 V apart
MPPT voltage range
90-435 V
150-550 V
90-435 V vs 150-550 V
Start voltage
90 V
130 V
-40 V for S6-EH1P3K-L-PLUS
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
21.0 A
22.0 A
+1.0 A for SPM 3000TL-HU
Efficiency
European efficiency
96.1 %
97.6 %
+1.5 pp for SPM 3000TL-HU
Max efficiency
96.2 %
98.1 %
+1.9 pp for SPM 3000TL-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60 V
40-60V
40-60 V vs 40-60V
Max charge current
210 A
140 A
+70 A for S6-EH1P3K-L-PLUS
Backup power
10.0 kW
-
Not published by Growatt
Physical
Weight
23.0 kg
26.0 kg
-3.0 kg for S6-EH1P3K-L-PLUS
Weight per kW
7.7 kg/kW
8.7 kg/kW
-1.0 kg/kW for S6-EH1P3K-L-PLUS
Dimensions
560x335x253 mm
330x580x230 mm
560x335x253 mm vs 330x580x230 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
natural
forced-air vs natural
Noise
65 dB
30 dB
-35 dB for SPM 3000TL-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Ginlong Solis S6-EH1P3K-L-PLUS vs SolarEdge SE3000H
10 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis S6-EH1P3K-L-PLUS vs Growatt MOD 3000TL3-HU
20 differences, the largest is european efficiency
Same type, similar size
Huawei
Ginlong Solis S6-EH1P3K-L-PLUS vs Huawei SUN2000L-3KTL
16 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 3000TL-HU vs Growatt MOD 3000TL3-XH
16 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.