Skip to main content
S6-EH1P16K03-NV-YD-L vs SUN-16K-SG01LP1-EU 9 of 23 identical Swap Change inverters

Ginlong Solis S6-EH1P16K03-NV-YD-L vs Deye SUN-16K-SG01LP1-EU

Ginlong Solis S6-EH1P16K03-NV-YD-L
Ginlong Solis
S6-EH1P16K03-NV-YD-L
16 kW 97.0 % euro Hybrid
VS
Deye
SUN-16K-SG01LP1-EU
16 kW 96.5 % euro Hybrid
The verdict

14 differences, and they point both ways

The largest is european efficiency: 0.5 pp more efficient. 9 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
9 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 23 parameters
Parameter S6-EH1P16K03-NV-YD-L SUN-16K-SG01LP1-EU Difference
European efficiency 97.0 % 96.5 % 0.5 pp more efficient
Max DC voltage 550 V 500 V 50 V apart
Max input current per tracker 20.0 A 26.0 A 6.0 A more headroom
Max PV power 25.60 kW 20.80 kW 4.80 kW apart
DC/AC ratio 1.60 1.30 0.30 more oversizing headroom
Weight 55.5 kg 48.5 kg 7.0 kg lighter
Noise 65 dB 30 dB 35 dB quieter
Weight per kW 3.5 kg/kW 3.0 kg/kW 0.4 kg/kW lighter
Max AC current 72.7 A 100.0 A 27.3 A apart
Start voltage 100 V 150 V 50 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 80-520 V 150-425 V 80-520 V vs 150-425 V
Battery voltage 40-60 V 40-60 40-60 V vs 40-60
Dimensions 845x459x313 mm 798x464x300 mm 845x459x313 mm vs 798x464x300 mm
02

Full specification

Parameter S6-EH1P16K03-NV-YD-L SUN-16K-SG01LP1-EU Difference
AC output
Rated AC power 16.00 kW 16.00 kW Same
Max AC power 16.00 kW 16.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 72.7 A 100.0 A 27.3 A apart
PV input
Max PV power 25.60 kW 20.80 kW 4.80 kW apart
DC/AC ratio 1.60 1.30 +0.30 for S6-EH1P16K03-NV-YD-L
Max DC voltage 550 V 500 V 50 V apart
MPPT voltage range 80-520 V 150-425 V 80-520 V vs 150-425 V
Start voltage 100 V 150 V -50 V for S6-EH1P16K03-NV-YD-L
MPP trackers 3 - Not published by Deye
Strings per tracker 2 2 Same
Max input current per tracker 20.0 A 26.0 A +6.0 A for SUN-16K-SG01LP1-EU
Efficiency
European efficiency 97.0 % 96.5 % +0.5 pp for S6-EH1P16K03-NV-YD-L
Max efficiency 97.6 % 97.6 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40-60 V 40-60 40-60 V vs 40-60
Max charge current - - Neither datasheet publishes this
Backup power - 12.0 kW Not published by Ginlong Solis
Physical
Weight 55.5 kg 48.5 kg -7.0 kg for SUN-16K-SG01LP1-EU
Weight per kW 3.5 kg/kW 3.0 kg/kW -0.4 kg/kW for SUN-16K-SG01LP1-EU
Dimensions 845x459x313 mm 798x464x300 mm 845x459x313 mm vs 798x464x300 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling forced-air forced-air Same
Noise 65 dB 30 dB -35 dB for SUN-16K-SG01LP1-EU
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-EH1P16K03-NV-YD-L vs Growatt MID 15KTL3-XH
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH1P16K03-NV-YD-L vs Growatt MID 17KTL3-XH
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH1P16K03-NV-YD-L vs Growatt MOD 15KTL3-HU
19 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.