Ginlong Solis S5-GC33K vs Growatt MID 33KTL3-X
VS
The verdict
7 differences, and they point both ways
The largest is max input current per tracker: 6.0 A more headroom. 15 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
15
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 22 parameters
What actually differs
Parameter
S5-GC33K
MID 33KTL3-X
Difference
Max input current per tracker
32.0 A
26.0 A
6.0 A more headroom
Max AC power
36.30 kW
36.60 kW
0.30 kW apart
Weight
38.2 kg
29.5 kg
8.7 kg lighter
European efficiency
98.2 %
98.5 %
0.3 pp more efficient
Start voltage
180 V
250 V
70 V earlier start
Weight per kW
1.2 kg/kW
0.9 kg/kW
0.3 kg/kW lighter
Dimensions
629x647x252 mm
435x580x230 mm
629x647x252 mm vs 435x580x230 mm
02
Full specification
Parameter
S5-GC33K
MID 33KTL3-X
Difference
AC output
Rated AC power
33.00 kW
33.00 kW
Same
Max AC power
36.30 kW
36.60 kW
0.30 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
55.1 A
55.5 A
Effectively the same
PV input
Max PV power
49.50 kW
49.50 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
180 V
250 V
-70 V for S5-GC33K
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
26.0 A
+6.0 A for S5-GC33K
Efficiency
European efficiency
98.2 %
98.5 %
+0.3 pp for MID 33KTL3-X
Max efficiency
98.7 %
98.8 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
38.2 kg
29.5 kg
-8.7 kg for MID 33KTL3-X
Weight per kW
1.2 kg/kW
0.9 kg/kW
-0.3 kg/kW for MID 33KTL3-X
Dimensions
629x647x252 mm
435x580x230 mm
629x647x252 mm vs 435x580x230 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
60 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Sungrow
Ginlong Solis S5-GC33K vs Sungrow SG33CX
5 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Ginlong Solis S5-GC33K vs Sungrow SG33T-P2-CN
6 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Ginlong Solis S5-GC33K vs Sungrow SG33CX-P2
8 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Growatt MID 33KTL3-X vs SOFAR 33KTLX-G3
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.