Skip to main content
RHI-6K-48ES-5G vs SUN2000-6KTL-M1 12 of 27 identical Swap Change inverters

Ginlong Solis RHI-6K-48ES-5G vs Huawei SUN2000-6KTL-M1

Ginlong Solis RHI-6K-48ES-5G
Ginlong Solis
RHI-6K-48ES-5G
6 kW 96.8 % euro Hybrid
VS
Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
The verdict

SUN2000-6KTL-M1 leads on the differences that matter

The largest is european efficiency: 0.9 pp more efficient. 12 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
12 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 27 parameters
Parameter RHI-6K-48ES-5G SUN2000-6KTL-M1 Difference
European efficiency 96.8 % 97.7 % 0.9 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max efficiency 97.5 % 98.6 % 1.1 pp more efficient
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Max PV power 8.00 kW 9.00 kW 1.00 kW apart
Max charge current 100 A 16 A 84 A faster charging
Backup power 5.0 kW 3.3 kW 1.7 kW more backup
DC/AC ratio 1.33 1.50 0.17 more oversizing headroom
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.1 A 16.0 A apart
Start voltage 120 V 200 V 80 V earlier start
MPPT voltage range 90-520 V 140-980 V 90-520 V vs 140-980 V
Battery voltage 42-58 V 600 V ~ 980 V 42-58 V vs 600 V ~ 980 V
Dimensions 505x333x249 mm 525x470x146 mm 505x333x249 mm vs 525x470x146 mm
02

Full specification

Parameter RHI-6K-48ES-5G SUN2000-6KTL-M1 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 26.1 A 10.1 A 16.0 A apart
PV input
Max PV power 8.00 kW 9.00 kW 1.00 kW apart
DC/AC ratio 1.33 1.50 +0.17 for SUN2000-6KTL-M1
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 90-520 V 140-980 V 90-520 V vs 140-980 V
Start voltage 120 V 200 V -80 V for RHI-6K-48ES-5G
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 11.0 A Same
Efficiency
European efficiency 96.8 % 97.7 % +0.9 pp for SUN2000-6KTL-M1
Max efficiency 97.5 % 98.6 % +1.1 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 V 600 V ~ 980 V 42-58 V vs 600 V ~ 980 V
Max charge current 100 A 16 A +84 A for RHI-6K-48ES-5G
Backup power 5.0 kW 3.3 kW +1.7 kW for RHI-6K-48ES-5G
Physical
Weight 17.0 kg 17.0 kg Same
Weight per kW 2.8 kg/kW 2.8 kg/kW Same
Dimensions 505x333x249 mm 525x470x146 mm 505x333x249 mm vs 525x470x146 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Ginlong Solis
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Ginlong Solis RHI-6K-48ES-5G vs SolarEdge SE6000H
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-6K-48ES-5G vs Growatt MOD 6000TL3-HU
18 differences, the largest is european efficiency
Same type, similar size
Huawei
Ginlong Solis RHI-6K-48ES-5G vs Huawei SUN2000-6KTL-L1
13 differences, the largest is european efficiency