Ginlong Solis RHI-3P5K-HVES-5G vs SolarEdge SE5000H
VS
The verdict
SE5000H leads on the differences that matter
The largest is european efficiency: 1.3 pp more efficient. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
8
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 19 parameters
What actually differs
Parameter
RHI-3P5K-HVES-5G
SE5000H
Difference
European efficiency
97.7 %
99.0 %
1.3 pp more efficient
Max DC voltage
1000 V
480 V
520 V apart
Max efficiency
98.4 %
99.2 %
0.8 pp more efficient
Max PV power
8.00 kW
10.00 kW
2.00 kW apart
DC/AC ratio
1.60
2.00
0.40 more oversizing headroom
Weight
25.1 kg
12.0 kg
13.1 kg lighter
Weight per kW
5.0 kg/kW
2.4 kg/kW
2.6 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.4 A
23.0 A
14.6 A apart
Dimensions
455x535x181 mm
459x370x154 mm
455x535x181 mm vs 459x370x154 mm
02
Full specification
Parameter
RHI-3P5K-HVES-5G
SE5000H
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.4 A
23.0 A
14.6 A apart
PV input
Max PV power
8.00 kW
10.00 kW
2.00 kW apart
DC/AC ratio
1.60
2.00
+0.40 for SE5000H
Max DC voltage
1000 V
480 V
520 V apart
MPPT voltage range
200-850 V
-
Not published by SolarEdge
Start voltage
160 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
2
-
Not published by SolarEdge
Max input current per tracker
26.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.7 %
99.0 %
+1.3 pp for SE5000H
Max efficiency
98.4 %
99.2 %
+0.8 pp for SE5000H
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-600V
-
Not published by SolarEdge
Max charge current
25 A
-
Not published by SolarEdge
Backup power
10.0 kW
-
Not published by SolarEdge
Physical
Weight
25.1 kg
12.0 kg
-13.1 kg for SE5000H
Weight per kW
5.0 kg/kW
2.4 kg/kW
-2.6 kg/kW for SE5000H
Dimensions
455x535x181 mm
459x370x154 mm
455x535x181 mm vs 459x370x154 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Ginlong Solis RHI-3P5K-HVES-5G vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
9 differences, the largest is european efficiency
Same type, similar size
Huawei
Ginlong Solis RHI-3P5K-HVES-5G vs Huawei SUN2000L-5KTL
16 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis RHI-3P5K-HVES-5G vs Growatt MOD 5000TL3-HU
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
SolarEdge SE5000H vs Huawei SUN2000-5KTL-L1
7 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.