Ginlong Solis RHI-3K-48ES-5G vs Growatt MOD 3000TL3-HU
VS
The verdict
18 differences, and they point both ways
The largest is european efficiency: 1.0 pp more efficient. 8 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 18 differencesHow alike are they
8
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
18 of 26 parameters
What actually differs
Parameter
RHI-3K-48ES-5G
MOD 3000TL3-HU
Difference
European efficiency
96.8 %
97.8 %
1.0 pp more efficient
Max DC voltage
600 V
1000 V
400 V apart
Max input current per tracker
11.0 A
20.0 A
9.0 A more headroom
Max efficiency
97.5 %
98.3 %
0.8 pp more efficient
Max AC power
3.00 kW
3.30 kW
0.30 kW apart
Max PV power
7.00 kW
6.00 kW
1.00 kW apart
DC/AC ratio
2.33
2.00
0.33 more oversizing headroom
Max charge current
100 A
25 A
75 A faster charging
Weight
17.0 kg
19.0 kg
2.0 kg lighter
Weight per kW
5.7 kg/kW
6.3 kg/kW
0.7 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
15.7 A
5.0 A
10.7 A apart
Start voltage
120 V
180 V
60 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
90-520 V
140-1000 V
90-520 V vs 140-1000 V
Battery voltage
42-58 V
600-980 V
42-58 V vs 600-980 V
Dimensions
505x333x249 mm
468x408x202 mm
505x333x249 mm vs 468x408x202 mm
02
Full specification
Parameter
RHI-3K-48ES-5G
MOD 3000TL3-HU
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.30 kW
0.30 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
15.7 A
5.0 A
10.7 A apart
PV input
Max PV power
7.00 kW
6.00 kW
1.00 kW apart
DC/AC ratio
2.33
2.00
+0.33 for RHI-3K-48ES-5G
Max DC voltage
600 V
1000 V
400 V apart
MPPT voltage range
90-520 V
140-1000 V
90-520 V vs 140-1000 V
Start voltage
120 V
180 V
-60 V for RHI-3K-48ES-5G
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
11.0 A
20.0 A
+9.0 A for MOD 3000TL3-HU
Efficiency
European efficiency
96.8 %
97.8 %
+1.0 pp for MOD 3000TL3-HU
Max efficiency
97.5 %
98.3 %
+0.8 pp for MOD 3000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
42-58 V
600-980 V
42-58 V vs 600-980 V
Max charge current
100 A
25 A
+75 A for RHI-3K-48ES-5G
Backup power
5.0 kW
-
Not published by Growatt
Physical
Weight
17.0 kg
19.0 kg
-2.0 kg for RHI-3K-48ES-5G
Weight per kW
5.7 kg/kW
6.3 kg/kW
-0.7 kg/kW for RHI-3K-48ES-5G
Dimensions
505x333x249 mm
468x408x202 mm
505x333x249 mm vs 468x408x202 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
29 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by Ginlong Solis
Warranty
Warranty
-
10 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Ginlong Solis RHI-3K-48ES-5G vs SolarEdge SE3000H
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-3K-48ES-5G vs Growatt SPM 3000TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Huawei
Ginlong Solis RHI-3K-48ES-5G vs Huawei SUN2000L-3KTL
10 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt MOD 3000TL3-XH
9 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.