Skip to main content
RHI-3.6K-48ES-5G vs MIN 3600TL-XA 9 of 17 identical Swap Change inverters

Ginlong Solis RHI-3.6K-48ES-5G vs Growatt MIN 3600TL-XA

Ginlong Solis RHI-3.6K-48ES-5G
Ginlong Solis
RHI-3.6K-48ES-5G
3.6 kW 96.8 % euro Hybrid
VS
Growatt MIN 3600TL-XA
Growatt
MIN 3600TL-XA
3.6 kW 97.2 % euro Hybrid
The verdict

MIN 3600TL-XA leads on the differences that matter

The largest is max efficiency: 0.7 pp more efficient. 9 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
9 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 17 parameters
Parameter RHI-3.6K-48ES-5G MIN 3600TL-XA Difference
Max efficiency 97.5 % 98.2 % 0.7 pp more efficient
European efficiency 96.8 % 97.2 % 0.4 pp more efficient
Max charge current 100 A 17 A 83 A faster charging
Weight 17.0 kg 10.8 kg 6.2 kg lighter
Weight per kW 4.7 kg/kW 3.0 kg/kW 1.7 kg/kW lighter
Max AC current 17.3 A 16.0 A 1.3 A apart
Battery voltage 42-58 V 360-550 V 42-58 V vs 360-550 V
Dimensions 505x333x249 mm 350x375x160 mm 505x333x249 mm vs 350x375x160 mm
02

Full specification

Parameter RHI-3.6K-48ES-5G MIN 3600TL-XA Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.60 kW 3.60 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 17.3 A 16.0 A 1.3 A apart
PV input
Max PV power 7.00 kW - Not published by Growatt
DC/AC ratio 1.94 - Not published by Growatt
Max DC voltage 600 V - Not published by Growatt
MPPT voltage range 90-520 V - Not published by Growatt
Start voltage 120 V - Not published by Growatt
MPP trackers 2 - Not published by Growatt
Strings per tracker 1 - Not published by Growatt
Max input current per tracker 11.0 A - Not published by Growatt
Efficiency
European efficiency 96.8 % 97.2 % +0.4 pp for MIN 3600TL-XA
Max efficiency 97.5 % 98.2 % +0.7 pp for MIN 3600TL-XA
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 V 360-550 V 42-58 V vs 360-550 V
Max charge current 100 A 17 A +83 A for RHI-3.6K-48ES-5G
Backup power 5.0 kW - Not published by Growatt
Physical
Weight 17.0 kg 10.8 kg -6.2 kg for MIN 3600TL-XA
Weight per kW 4.7 kg/kW 3.0 kg/kW -1.7 kg/kW for MIN 3600TL-XA
Dimensions 505x333x249 mm 350x375x160 mm 505x333x249 mm vs 350x375x160 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Ginlong Solis
Arc fault protection Yes - Not published by Growatt
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 10 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis RHI-3.6K-48ES-5G vs Growatt SPM 3600TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-3.6K-48ES-5G vs Growatt MIN 3600TL-XH
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis RHI-3.6K-48ES-5G vs Growatt MIN 3600TL-XH2
15 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Growatt MIN 3600TL-XA vs GoodWe GW3600N-EH
7 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.