Fronius Verto 33.3 Plus vs Ginlong Solis S6-EH3P35K-H-LV(21A)

Fronius International
Fronius Verto 33.3 Plus
33.3 kW
98.0 % euro
Hybrid
VS
The verdict
Fronius Verto 33.3 Plus leads on the differences that matter
The largest is rated ac power: 1.70 kW apart. 9 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
9
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 25 parameters
What actually differs
Parameter
Fronius Verto 33.3 Plus
S6-EH3P35K-H-LV(21A)
Difference
Rated AC power
33.30 kW
35.00 kW
1.70 kW apart
European efficiency
98.0 %
95.5 %
2.5 pp more efficient
Max input current per tracker
28.0 A
42.0 A
14.0 A more headroom
Max efficiency
98.2 %
96.3 %
1.9 pp more efficient
Max AC power
33.30 kW
35.00 kW
1.70 kW apart
Max PV power
39.00 kW
70.00 kW
31.00 kW apart
DC/AC ratio
1.17
2.00
0.83 more oversizing headroom
Max charge current
50 A
160 A
110 A faster charging
Weight
43.0 kg
76.0 kg
33.0 kg lighter
Weight per kW
1.3 kg/kW
2.2 kg/kW
0.9 kg/kW lighter
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
50.5 A
152.0 A
101.5 A apart
Start voltage
150 V
180 V
30 V earlier start
MPPT voltage range
150-870 V
150-850 V
150-870 V vs 150-850 V
Battery voltage
150-700
150 - 800 V
150-700 vs 150 - 800 V
Dimensions
865x574x279 mm
880x530x290 mm
865x574x279 mm vs 880x530x290 mm
02
Full specification
Parameter
Fronius Verto 33.3 Plus
S6-EH3P35K-H-LV(21A)
Difference
AC output
Rated AC power
33.30 kW
35.00 kW
1.70 kW apart
Max AC power
33.30 kW
35.00 kW
1.70 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
50.5 A
152.0 A
101.5 A apart
PV input
Max PV power
39.00 kW
70.00 kW
31.00 kW apart
DC/AC ratio
1.17
2.00
+0.83 for S6-EH3P35K-H-LV(21A)
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
150-870 V
150-850 V
150-870 V vs 150-850 V
Start voltage
150 V
180 V
-30 V for Fronius Verto 33.3 Plus
MPP trackers
3
3
Same
Strings per tracker
2
2
Same
Max input current per tracker
28.0 A
42.0 A
+14.0 A for S6-EH3P35K-H-LV(21A)
Efficiency
European efficiency
98.0 %
95.5 %
+2.5 pp for Fronius Verto 33.3 Plus
Max efficiency
98.2 %
96.3 %
+1.9 pp for Fronius Verto 33.3 Plus
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
150-700
150 - 800 V
150-700 vs 150 - 800 V
Max charge current
50 A
160 A
+110 A for S6-EH3P35K-H-LV(21A)
Backup power
-
35.0 kW
Not published by Fronius International
Physical
Weight
43.0 kg
76.0 kg
-33.0 kg for Fronius Verto 33.3 Plus
Weight per kW
1.3 kg/kW
2.2 kg/kW
-0.9 kg/kW for Fronius Verto 33.3 Plus
Dimensions
865x574x279 mm
880x530x290 mm
865x574x279 mm vs 880x530x290 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
57 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Fronius Verto 33.3 Plus vs Growatt MID 33K-HU
14 differences, the largest is rated ac power
Same type, similar size
Deye
Fronius Verto 33.3 Plus vs Deye SUN-35K-SG01HP3-EU-BM3
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Fronius Verto 33.3 Plus vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
15 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2
8 differences, the largest is max efficiency
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt MID 36K-HU
16 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.