Skip to main content
Fronius Verto 20.0 vs STP 20-US-50 (Sunny Tripower X-US 20) 15 of 24 identical Swap Change inverters

Fronius Verto 20.0 vs SMA Solar STP 20-US-50 (Sunny Tripower X-US 20)

Fronius Verto 20.0
Fronius International
Fronius Verto 20.0
20 kW 98.3 % euro Grid-tie
VS
SMA Solar STP 20-US-50 (Sunny Tripower X-US 20)
SMA Solar
STP 20-US-50 (Sunny Tripower X-US 20)
20 kW Grid-tie
The verdict

Fronius Verto 20.0 leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 15 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
15 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 24 parameters
Parameter Fronius Verto 20.0 STP 20-US-50 (Sunny Tripower X-US 20) Difference
Max input current per tracker 28.0 A 24.0 A 4.0 A more headroom
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 30.3 A 24.0 A 6.3 A apart
MPP trackers 4 3 1 tracker more
Start voltage 150 V 188 V 38 V earlier start
Ingress protection IP66 Type 4X (UL 50E) IP66 vs Type 4X (UL 50E)
Noise 56 dB 59 dB 2 dB quieter
MPPT voltage range 150-870 V 150-1000 V 150-870 V vs 150-1000 V
Dimensions 730x540x278 mm 762x728x266 mm 730x540x278 mm vs 762x728x266 mm
02

Full specification

Parameter Fronius Verto 20.0 STP 20-US-50 (Sunny Tripower X-US 20) Difference
AC output
Rated AC power 20.00 kW 20.00 kW Same
Max AC power 20.00 kW 20.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 30.3 A 24.0 A 6.3 A apart
PV input
Max PV power 30.00 kW 30.00 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 150-870 V 150-1000 V 150-870 V vs 150-1000 V
Start voltage 150 V 188 V -38 V for Fronius Verto 20.0
MPP trackers 4 3 +1 trackers for Fronius Verto 20.0
Strings per tracker 2 2 Same
Max input current per tracker 28.0 A 24.0 A +4.0 A for Fronius Verto 20.0
Efficiency
European efficiency 98.3 % - Not published by SMA Solar
Max efficiency 98.6 % - Not published by SMA Solar
CEC efficiency - 97.5 % Not published by Fronius International
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 35.2 kg 35.0 kg Effectively the same
Weight per kW 1.8 kg/kW 1.8 kg/kW Same
Dimensions 730x540x278 mm 762x728x266 mm 730x540x278 mm vs 762x728x266 mm
Ingress protection IP66 Type 4X (UL 50E) IP66 vs Type 4X (UL 50E)
Cooling forced-air forced-air Same
Noise 56 dB 59 dB -2 dB for Fronius Verto 20.0
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - 10 yrs Not published by Fronius International
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Fronius Verto 20.0 vs Growatt MID 20KTL3-X
11 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Fronius Verto 20.0 vs Sungrow SG20KTL-M
10 differences, the largest is max dc voltage
Same type, similar size
Huawei
Fronius Verto 20.0 vs Huawei SUN2000-20KTL-M2
12 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.