Fronius Primo GEN24 4.6 Plus vs Huawei SUN2000L-4.6KTL
Fronius International
Fronius Primo GEN24 4.6 Plus
4.6 kW
97.2 % euro
Hybrid
VS
The verdict
SUN2000L-4.6KTL leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 9 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
9
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 24 parameters
What actually differs
Parameter
Fronius Primo GEN24 4.6 Plus
SUN2000L-4.6KTL
Difference
European efficiency
97.2 %
98.0 %
0.8 pp more efficient
Max input current per tracker
22.0 A
11.0 A
11.0 A more headroom
Max efficiency
97.6 %
98.6 %
1.0 pp more efficient
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Max charge current
22 A
10 A
12 A faster charging
Weight
15.4 kg
10.6 kg
4.8 kg lighter
Weight per kW
3.3 kg/kW
2.3 kg/kW
1.0 kg/kW lighter
Max AC current
20.9 A
23.0 A
2.1 A apart
Start voltage
80 V
120 V
40 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
65-530 V
120-480 V
65-530 V vs 120-480 V
Battery voltage
150-455 V
350-450 Vdc
150-455 V vs 350-450 Vdc
Strings per tracker
2
1
1 string apart
Dimensions
530x474x165 mm
375x375x162 mm
530x474x165 mm vs 375x375x162 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
Fronius Primo GEN24 4.6 Plus
SUN2000L-4.6KTL
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.9 A
23.0 A
2.1 A apart
PV input
Max PV power
4.75 kW
-
Not published by Huawei
DC/AC ratio
1.03
-
Not published by Huawei
Max DC voltage
600 V
600 V
Same
MPPT voltage range
65-530 V
120-480 V
65-530 V vs 120-480 V
Start voltage
80 V
120 V
-40 V for Fronius Primo GEN24 4.6 Plus
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
22.0 A
11.0 A
+11.0 A for Fronius Primo GEN24 4.6 Plus
Efficiency
European efficiency
97.2 %
98.0 %
+0.8 pp for SUN2000L-4.6KTL
Max efficiency
97.6 %
98.6 %
+1.0 pp for SUN2000L-4.6KTL
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
150-455 V
350-450 Vdc
150-455 V vs 350-450 Vdc
Max charge current
22 A
10 A
+12 A for Fronius Primo GEN24 4.6 Plus
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.4 kg
10.6 kg
-4.8 kg for SUN2000L-4.6KTL
Weight per kW
3.3 kg/kW
2.3 kg/kW
-1.0 kg/kW for SUN2000L-4.6KTL
Dimensions
530x474x165 mm
375x375x162 mm
530x474x165 mm vs 375x375x162 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
natural
forced-air vs natural
Noise
42 dB
-
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Huawei
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Fronius Primo GEN24 4.6 Plus vs Huawei SUN2000-4.6KTL-L1
16 differences, the largest is european efficiency
Same type, similar size
Growatt
Fronius Primo GEN24 4.6 Plus vs Growatt SPM 4600TL-HU
16 differences, the largest is european efficiency
Same type, similar size
Growatt
Fronius Primo GEN24 4.6 Plus vs Growatt MIN 4600TL-XH
16 differences, the largest is max dc voltage
Same type, similar size
Growatt
Huawei SUN2000L-4.6KTL vs Growatt MIN 4600TL-XA
7 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.