Parameter
Fronius Primo 4.6-1
MIN 4600TL-X2 (Pro)
Difference
European efficiency
97.0 %
97.5 %
0.5 pp more efficient
Max DC voltage
1000 V
550 V
450 V apart
Weight
21.5 kg
10.8 kg
10.7 kg lighter
Weight per kW
4.7 kg/kW
2.3 kg/kW
2.3 kg/kW lighter
Max efficiency
98.1 %
98.4 %
0.3 pp more efficient
Max operating temperature
55 °C
60 °C
5 °C more heat tolerant
Start voltage
80 V
50 V
30 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
80-800 V
40-550 V
80-800 V vs 40-550 V
Max AC current
20.0 A
20.9 A
0.9 A apart
Strings per tracker
2
1
1 string apart
Dimensions
645x431x204 mm
350x375x158 mm
645x431x204 mm vs 350x375x158 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
Fronius Primo 4.6-1
MIN 4600TL-X2 (Pro)
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
4.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.0 A
20.9 A
0.9 A apart
PV input
Max PV power
6.90 kW
6.90 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1000 V
550 V
450 V apart
MPPT voltage range
80-800 V
40-550 V
80-800 V vs 40-550 V
Start voltage
80 V
50 V
-30 V for MIN 4600TL-X2 (Pro)
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
18.0 A
18.0 A
Same
Efficiency
European efficiency
97.0 %
97.5 %
+0.5 pp for MIN 4600TL-X2 (Pro)
Max efficiency
98.1 %
98.4 %
+0.3 pp for MIN 4600TL-X2 (Pro)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
21.5 kg
10.8 kg
-10.7 kg for MIN 4600TL-X2 (Pro)
Weight per kW
4.7 kg/kW
2.3 kg/kW
-2.3 kg/kW for MIN 4600TL-X2 (Pro)
Dimensions
645x431x204 mm
350x375x158 mm
645x431x204 mm vs 350x375x158 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
55 °C
60 °C
+5 °C for MIN 4600TL-X2 (Pro)
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Fronius Primo 4.6-1 vs GoodWe GW4600-SS
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Fronius Primo 4.6-1 vs Growatt MIN 4600TL-X
16 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Fronius Primo 4.6-1 vs Fronius Primo 5.0-1 AUS
4 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MIN 4600TL-X2 (Pro) vs Ginlong Solis S6-GR1P4.6K
11 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.