Skip to main content
Fronius Primo 4.6-1 vs MIN 4600TL-X2 (Pro) 9 of 22 identical Swap Change inverters

Fronius Primo 4.6-1 vs Growatt MIN 4600TL-X2 (Pro)

Fronius Primo 4.6-1
Fronius International
Fronius Primo 4.6-1
4.6 kW 97.0 % euro Grid-tie
VS
Growatt MIN 4600TL-X2 (Pro)
Growatt
MIN 4600TL-X2 (Pro)
4.6 kW 97.5 % euro Grid-tie
The verdict

MIN 4600TL-X2 (Pro) leads on the differences that matter

The largest is european efficiency: 0.5 pp more efficient. 9 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
9 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 22 parameters
Parameter Fronius Primo 4.6-1 MIN 4600TL-X2 (Pro) Difference
European efficiency 97.0 % 97.5 % 0.5 pp more efficient
Max DC voltage 1000 V 550 V 450 V apart
Weight 21.5 kg 10.8 kg 10.7 kg lighter
Weight per kW 4.7 kg/kW 2.3 kg/kW 2.3 kg/kW lighter
Max efficiency 98.1 % 98.4 % 0.3 pp more efficient
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
Start voltage 80 V 50 V 30 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 80-800 V 40-550 V 80-800 V vs 40-550 V
Max AC current 20.0 A 20.9 A 0.9 A apart
Strings per tracker 2 1 1 string apart
Dimensions 645x431x204 mm 350x375x158 mm 645x431x204 mm vs 350x375x158 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter Fronius Primo 4.6-1 MIN 4600TL-X2 (Pro) Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 4.60 kW 4.60 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 20.0 A 20.9 A 0.9 A apart
PV input
Max PV power 6.90 kW 6.90 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1000 V 550 V 450 V apart
MPPT voltage range 80-800 V 40-550 V 80-800 V vs 40-550 V
Start voltage 80 V 50 V -30 V for MIN 4600TL-X2 (Pro)
MPP trackers 2 2 Same
Strings per tracker 2 1 1 string apart
Max input current per tracker 18.0 A 18.0 A Same
Efficiency
European efficiency 97.0 % 97.5 % +0.5 pp for MIN 4600TL-X2 (Pro)
Max efficiency 98.1 % 98.4 % +0.3 pp for MIN 4600TL-X2 (Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 21.5 kg 10.8 kg -10.7 kg for MIN 4600TL-X2 (Pro)
Weight per kW 4.7 kg/kW 2.3 kg/kW -2.3 kg/kW for MIN 4600TL-X2 (Pro)
Dimensions 645x431x204 mm 350x375x158 mm 645x431x204 mm vs 350x375x158 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 60 °C +5 °C for MIN 4600TL-X2 (Pro)
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Fronius Primo 4.6-1 vs GoodWe GW4600-SS
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Fronius Primo 4.6-1 vs Growatt MIN 4600TL-X
16 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Fronius Primo 4.6-1 vs Fronius Primo 5.0-1 AUS
4 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MIN 4600TL-X2 (Pro) vs Ginlong Solis S6-GR1P4.6K
11 differences, the largest is max dc voltage
04

Written summary