POW-HVM6200W-48V vs ESI-6.5K-T1 1 of 18 identical Swap Change inverters

Easun Power POW-HVM6200W-48V vs Sofar Solar ESI-6.5K-T1

Easun Power
POW-HVM6200W-48V
6.2 kW Hybrid
VS
Sofar Solar ESI-6.5K-T1
Sofar Solar
ESI-6.5K-T1
6.5 kW 97.0 % euro Hybrid
The verdict

17 differences, and they point both ways

The largest is rated ac power: 0.30 kW apart. 1 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
1 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 18 parameters
Parameter POW-HVM6200W-48V ESI-6.5K-T1 Difference
Rated AC power 6.20 kW 6.50 kW 0.30 kW apart
Max DC voltage 500 V 1000 V 500 V apart
Max input current per tracker 27.0 A 20.0 A 7.0 A more headroom
Max efficiency 94.0 % 98.0 % 4.0 pp more efficient
Max AC power 6.20 kW 7.15 kW 0.95 kW apart
Max PV power 6.50 kW 13.00 kW 6.50 kW apart
DC/AC ratio 1.05 2.00 0.95 more oversizing headroom
MPP trackers 1 3 2 trackers more
Max charge current 120 A 25 A 95 A faster charging
Weight 9.0 kg 30.0 kg 21.0 kg lighter
Weight per kW 1.5 kg/kW 4.6 kg/kW 3.2 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max operating temperature 55 °C 60 °C 5 °C more heat tolerant
MPPT voltage range 60-500 V 160-950 V 60-500 V vs 160-950 V
Dimensions 122x312x438 mm 440x708x170 mm 122x312x438 mm vs 440x708x170 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter POW-HVM6200W-48V ESI-6.5K-T1 Difference
AC output
Rated AC power 6.20 kW 6.50 kW 0.30 kW apart
Max AC power 6.20 kW 7.15 kW 0.95 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current - 10.9 A Not published by Easun Power
PV input
Max PV power 6.50 kW 13.00 kW 6.50 kW apart
DC/AC ratio 1.05 2.00 +0.95 for ESI-6.5K-T1
Max DC voltage 500 V 1000 V 500 V apart
MPPT voltage range 60-500 V 160-950 V 60-500 V vs 160-950 V
Start voltage - 200 V Not published by Easun Power
MPP trackers 1 3 +2 trackers for ESI-6.5K-T1
Strings per tracker - 1 Not published by Easun Power
Max input current per tracker 27.0 A 20.0 A +7.0 A for POW-HVM6200W-48V
Efficiency
European efficiency - 97.0 % Not published by Easun Power
Max efficiency 94.0 % 98.0 % +4.0 pp for ESI-6.5K-T1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage - 350-435 Vdc Not published by Easun Power
Max charge current 120 A 25 A +95 A for POW-HVM6200W-48V
Backup power 6.2 kW - Not published by Sofar Solar
Physical
Weight 9.0 kg 30.0 kg -21.0 kg for POW-HVM6200W-48V
Weight per kW 1.5 kg/kW 4.6 kg/kW -3.2 kg/kW for POW-HVM6200W-48V
Dimensions 122x312x438 mm 440x708x170 mm 122x312x438 mm vs 440x708x170 mm
Ingress protection - IP66 Not published by Easun Power
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 60 °C +5 °C for ESI-6.5K-T1
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Easun Power
Integrated DC switch - Yes Not published by Easun Power
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Easun Power
Easun Power POW-HVM6200W-48V vs Easun Power 6.2KVA (PVmax=500V, 48V battery)
One difference: dimensions
Same type, similar size
Easun Power
Easun Power POW-HVM6200W-48V vs Easun Power 6.2KVA (48V)
One difference: weight
Same type, similar size
Easun Power
Easun Power POW-HVM6200W-48V vs Easun Power POW-HVM6.2K-PRO (6.2KW)
8 differences, the largest is max efficiency
Same type, similar size
GoodWe
Sofar Solar ESI-6.5K-T1 vs GoodWe GW6.5KN-ET (ET PLUS+ 16A Series)
11 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Sofar Solar ESI-6.5K-T1 vs GoodWe GW6.5KN-ET
11 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.