Easun Power POW-HVM6.2KP vs Easun Power POW-HVM6200W-48V
VS
The verdict
HVM6.2KP leads on the differences that matter
The largest is max efficiency: 4.0 pp more efficient. 11 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
11
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 19 parameters
What actually differs
Parameter
HVM6.2KP
HVM6200W-48V
Difference
Max efficiency
98.0 %
94.0 %
4.0 pp more efficient
Max AC power
6.50 kW
6.20 kW
0.30 kW apart
Max PV power
8.50 kW
6.50 kW
2.00 kW apart
DC/AC ratio
1.37
1.05
0.32 more oversizing headroom
Weight
10.7 kg
9.0 kg
1.7 kg lighter
Max operating temperature
50 °C
55 °C
5 °C more heat tolerant
Weight per kW
1.7 kg/kW
1.5 kg/kW
0.3 kg/kW lighter
Dimensions
120x310x510 mm
122x312x438 mm
120x310x510 mm vs 122x312x438 mm
02
Full specification
Parameter
HVM6.2KP
HVM6200W-48V
Difference
AC output
Rated AC power
6.20 kW
6.20 kW
Same
Max AC power
6.50 kW
6.20 kW
0.30 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
26.9 A
-
Not published by Easun Power
PV input
Max PV power
8.50 kW
6.50 kW
2.00 kW apart
DC/AC ratio
1.37
1.05
+0.32 for HVM6.2KP
Max DC voltage
500 V
500 V
Same
MPPT voltage range
60-500 V
60-500 V
Same
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
1
1
Same
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
27.0 A
27.0 A
Same
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
98.0 %
94.0 %
+4.0 pp for HVM6.2KP
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
120 A
120 A
Same
Backup power
6.2 kW
6.2 kW
Same
Physical
Weight
10.7 kg
9.0 kg
-1.7 kg for HVM6200W-48V
Weight per kW
1.7 kg/kW
1.5 kg/kW
-0.3 kg/kW for HVM6200W-48V
Dimensions
120x310x510 mm
122x312x438 mm
120x310x510 mm vs 122x312x438 mm
Ingress protection
-
-
Neither datasheet publishes this
Cooling
forced-air
forced-air
Same
Noise
50 dB
-
Not published by Easun Power
Max operating temperature
50 °C
55 °C
+5 °C for HVM6200W-48V
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Easun Power
Easun Power POW-HVM6.2KP vs Easun Power 6.2KVA (PVmax=500V, 48V battery)
8 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power POW-HVM6.2KP vs Easun Power 6.2KVA (48V)
6 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power POW-HVM6.2KP vs Easun Power POW-HVM6.2K-PRO (6.2KW)
6 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.