Easun Power ISolar SWP 8000 vs Growatt SPF 8000T DVM
VS
The verdict
ISolar SWP 8000 leads on the differences that matter
The largest is max pv power: 1.00 kW apart. 2 of 7 comparable parameters are identical, with 25 more left out because at least one datasheet does not publish them.
See all 5 differencesHow alike are they
2
of 7 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
5 of 7 parameters
What actually differs
Parameter
ISolar SWP 8000
SPF 8000T DVM
Difference
Max PV power
8.00 kW
7.00 kW
1.00 kW apart
Weight
33.0 kg
64.0 kg
31.0 kg lighter
Weight per kW
4.1 kg/kW
8.0 kg/kW
3.9 kg/kW lighter
DC/AC ratio
1.00
0.88
0.12 more oversizing headroom
Dimensions
665x435x665 mm
650x380x225 mm
665x435x665 mm vs 650x380x225 mm
02
Full specification
Parameter
ISolar SWP 8000
SPF 8000T DVM
Difference
AC output
Rated AC power
8.00 kW
8.00 kW
Same
Max AC power
8.00 kW
8.00 kW
Same
Grid connection
-
Single-phase
Not published by Easun Power
Nominal AC voltage
-
240 V
Not published by Easun Power
Max AC current
-
-
Neither datasheet publishes this
PV input
Max PV power
8.00 kW
7.00 kW
1.00 kW apart
DC/AC ratio
1.00
0.88
+0.12 for ISolar SWP 8000
Max DC voltage
-
150 V
Not published by Easun Power
MPPT voltage range
-
60-145 V
Not published by Easun Power
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
-
98.0 %
Not published by Easun Power
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
Yes
Not published by Easun Power
Battery voltage
-
48VDC
Not published by Easun Power
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
33.0 kg
64.0 kg
-31.0 kg for ISolar SWP 8000
Weight per kW
4.1 kg/kW
8.0 kg/kW
-3.9 kg/kW for ISolar SWP 8000
Dimensions
665x435x665 mm
650x380x225 mm
665x435x665 mm vs 650x380x225 mm
Ingress protection
-
IP20
Not published by Easun Power
Cooling
forced-air
-
Not published by Growatt
Noise
60 dB
-
Not published by Growatt
Max operating temperature
-
45 °C
Not published by Easun Power
Connectivity and safety
Wi-Fi
-
Yes
Not published by Easun Power
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Easun Power ISolar SWP 8000 vs Growatt SPF 8000T DVM-MPV
5 differences, the largest is max pv power
Same type, similar size
Easun Power
Easun Power ISolar SWP 8000 vs Easun Power ISolar SMW 8KW
3 differences, the largest is weight
Same type, similar size
Easun Power
Easun Power ISolar SWP 8000 vs Easun Power ISolar SMW II 8000
3 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.