Easun Power ISolar MLV-5KW-U vs Growatt SPF 5000T DVM-MPV
VS
The verdict
3 differences, none of them an advantage
The largest is max dc voltage: 250 V apart. 3 of 6 comparable parameters are identical, with 26 more left out because at least one datasheet does not publish them.
See all 3 differencesHow alike are they
3
of 6 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
3 of 6 parameters
What actually differs
Parameter
ISolar MLV-5KW-U
SPF 5000T DVM-MPV
Difference
Max DC voltage
500 V
250 V
250 V apart
Nominal AC voltage
120 V
240 V
120 V apart
MPPT voltage range
120-500 V
60-245 V
120-500 V vs 60-245 V
02
Full specification
Parameter
ISolar MLV-5KW-U
SPF 5000T DVM-MPV
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.00 kW
Same
Grid connection
Single-phase
-
Not published by Growatt
Nominal AC voltage
120 V
240 V
120 V apart
Max AC current
63.0 A
-
Not published by Growatt
PV input
Max PV power
-
5.00 kW
Not published by Easun Power
DC/AC ratio
-
1.00
Not published by Easun Power
Max DC voltage
500 V
250 V
250 V apart
MPPT voltage range
120-500 V
60-245 V
120-500 V vs 60-245 V
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
-
85.0 %
Not published by Easun Power
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40.0-60.0 Vdc (rated 48V; minimum start 44V)
-
Not published by Growatt
Max charge current
40 A
-
Not published by Growatt
Backup power
5.0 kW
-
Not published by Growatt
Physical
Weight
-
47.0 kg
Not published by Easun Power
Weight per kW
-
9.4 kg/kW
Not published by Easun Power
Dimensions
-
540x360x218 mm
Not published by Easun Power
Ingress protection
-
IP20
Not published by Easun Power
Cooling
forced-air
-
Not published by Growatt
Noise
-
-
Neither datasheet publishes this
Max operating temperature
-
45 °C
Not published by Easun Power
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Easun Power ISolar MLV-5KW-U vs Growatt SPF 5000 ES
4 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power ISolar MLV-5KW-U vs Growatt SPF 5000T DVM
4 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power ISolar MLV-5KW-U vs Growatt SPF 3500 ES Lite
3 differences, the largest is nominal ac voltage
Same type, similar size
Growatt
Growatt SPF 5000T DVM-MPV vs Growatt SPF 5000 ES Lite
9 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.