Easun Power IGrid WP LV 10KW vs Huawei SUN2000-10KTL-M1
VS
The verdict
SUN2000-10KTL-M1 leads on the differences that matter
The largest is max efficiency: 2.6 pp more efficient. 1 of 9 comparable parameters are identical, with 23 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
1
of 9 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 9 parameters
What actually differs
Parameter
IGrid WP LV 10KW
SUN2000-10KTL-M1
Difference
Max efficiency
96.0 %
98.6 %
2.6 pp more efficient
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Max PV power
14.50 kW
15.00 kW
0.50 kW apart
Weight
50.0 kg
17.0 kg
33.0 kg lighter
Weight per kW
5.0 kg/kW
1.7 kg/kW
3.3 kg/kW lighter
DC/AC ratio
1.45
1.50
0.05 more oversizing headroom
Dimensions
575x500x575 mm
525x470x146 mm
575x500x575 mm vs 525x470x146 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
IGrid WP LV 10KW
SUN2000-10KTL-M1
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Grid connection
-
3-phase
Not published by Easun Power
Nominal AC voltage
-
400 V
Not published by Easun Power
Max AC current
-
16.9 A
Not published by Easun Power
PV input
Max PV power
14.50 kW
15.00 kW
0.50 kW apart
DC/AC ratio
1.45
1.50
+0.05 for SUN2000-10KTL-M1
Max DC voltage
-
1100 V
Not published by Easun Power
MPPT voltage range
-
140-980 V
Not published by Easun Power
Start voltage
-
200 V
Not published by Easun Power
MPP trackers
-
2
Not published by Easun Power
Strings per tracker
-
1
Not published by Easun Power
Max input current per tracker
-
11.0 A
Not published by Easun Power
Efficiency
European efficiency
-
98.1 %
Not published by Easun Power
Max efficiency
96.0 %
98.6 %
+2.6 pp for SUN2000-10KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
Yes
Not published by Easun Power
Battery voltage
-
600 V ~ 980 V
Not published by Easun Power
Max charge current
-
16 A
Not published by Easun Power
Backup power
-
3.3 kW
Not published by Easun Power
Physical
Weight
50.0 kg
17.0 kg
-33.0 kg for SUN2000-10KTL-M1
Weight per kW
5.0 kg/kW
1.7 kg/kW
-3.3 kg/kW for SUN2000-10KTL-M1
Dimensions
575x500x575 mm
525x470x146 mm
575x500x575 mm vs 525x470x146 mm
Ingress protection
-
IP65
Not published by Easun Power
Cooling
forced-air
natural
forced-air vs natural
Noise
60 dB
-
Not published by Huawei
Max operating temperature
-
60 °C
Not published by Easun Power
Connectivity and safety
Wi-Fi
-
Yes
Not published by Easun Power
Ethernet
-
Yes
Not published by Easun Power
Arc fault protection
-
Yes
Not published by Easun Power
Integrated DC switch
-
Yes
Not published by Easun Power
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Easun Power IGrid WP LV 10KW vs SolarEdge SE10000H
7 differences, the largest is max efficiency
Same type, similar size
Growatt
Easun Power IGrid WP LV 10KW vs Growatt MOD 10KTL3-XH
8 differences, the largest is max efficiency
Same type, similar size
Growatt
Easun Power IGrid WP LV 10KW vs Growatt MOD 10KTL3-HU
8 differences, the largest is max efficiency
Same type, similar size
Huawei
Huawei SUN2000-10KTL-M1 vs Huawei SUN2000-10KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.