Easun Power 8.5KW (8.5KVA/8.5KW, 48V) vs Growatt MIN 8200TL-XH-US
VS
The verdict
17 differences, and they point both ways
The largest is rated ac power: 0.30 kW apart. 2 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
2
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 19 parameters
What actually differs
Parameter
8.5KW (8.5KVA/8.5KW, 48V)
MIN 8200TL-XH-US
Difference
Rated AC power
8.50 kW
8.20 kW
0.30 kW apart
Max DC voltage
500 V
600 V
100 V apart
Max input current per tracker
18.0 A
13.5 A
4.5 A more headroom
Max efficiency
94.0 %
98.3 %
4.3 pp more efficient
Max AC power
8.50 kW
8.20 kW
0.30 kW apart
Max PV power
10.00 kW
16.40 kW
6.40 kW apart
DC/AC ratio
1.18
2.00
0.82 more oversizing headroom
MPP trackers
2
4
2 trackers more
Max charge current
160 A
30 A
130 A faster charging
Weight
14.4 kg
20.5 kg
6.1 kg lighter
Weight per kW
1.7 kg/kW
2.5 kg/kW
0.8 kg/kW lighter
Max operating temperature
55 °C
60 °C
5 °C more heat tolerant
Nominal AC voltage
230 V
240 V
10 V apart
MPPT voltage range
60-500 V
50-550 V
60-500 V vs 50-550 V
Strings per tracker
1
2
1 string apart
Dimensions
122x403x540 mm
638x400x187 mm
122x403x540 mm vs 638x400x187 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
8.5KW (8.5KVA/8.5KW, 48V)
MIN 8200TL-XH-US
Difference
AC output
Rated AC power
8.50 kW
8.20 kW
0.30 kW apart
Max AC power
8.50 kW
8.20 kW
0.30 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
-
35.0 A
Not published by Easun Power
PV input
Max PV power
10.00 kW
16.40 kW
6.40 kW apart
DC/AC ratio
1.18
2.00
+0.82 for MIN 8200TL-XH-US
Max DC voltage
500 V
600 V
100 V apart
MPPT voltage range
60-500 V
50-550 V
60-500 V vs 50-550 V
Start voltage
-
50 V
Not published by Easun Power
MPP trackers
2
4
+2 trackers for MIN 8200TL-XH-US
Strings per tracker
1
2
1 string apart
Max input current per tracker
18.0 A
13.5 A
+4.5 A for 8.5KW (8.5KVA/8.5KW, 48V)
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
94.0 %
98.3 %
+4.3 pp for MIN 8200TL-XH-US
CEC efficiency
-
97.5 %
Not published by Easun Power
Battery
Battery input
Yes
Yes
Same
Battery voltage
-
360-550 V
Not published by Easun Power
Max charge current
160 A
30 A
+130 A for 8.5KW (8.5KVA/8.5KW, 48V)
Backup power
-
11.4 kW
Not published by Easun Power
Physical
Weight
14.4 kg
20.5 kg
-6.1 kg for 8.5KW (8.5KVA/8.5KW, 48V)
Weight per kW
1.7 kg/kW
2.5 kg/kW
-0.8 kg/kW for 8.5KW (8.5KVA/8.5KW, 48V)
Dimensions
122x403x540 mm
638x400x187 mm
122x403x540 mm vs 638x400x187 mm
Ingress protection
-
NEMA 4X (IP65)
Not published by Easun Power
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
55 °C
60 °C
+5 °C for MIN 8200TL-XH-US
Connectivity and safety
Wi-Fi
-
Yes
Not published by Easun Power
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Easun Power
Integrated DC switch
-
Yes
Not published by Easun Power
Warranty
Warranty
-
10 yrs
Not published by Easun Power
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Easun Power 8.5KW (8.5KVA/8.5KW, 48V) vs SolarEdge SE8000H
11 differences, the largest is rated ac power
Same type, similar size
Growatt
Easun Power 8.5KW (8.5KVA/8.5KW, 48V) vs Growatt MOD 8000TL3-XH
13 differences, the largest is rated ac power
Same type, similar size
Growatt
Easun Power 8.5KW (8.5KVA/8.5KW, 48V) vs Growatt MOD 9000TL3-XH
13 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MIN 8200TL-XH-US vs Growatt MOD 8000TL3-HU
18 differences, the largest is rated ac power
Same type, similar size
Huawei
Growatt MIN 8200TL-XH-US vs Huawei SUN5000-8K-MAP0
19 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.