Skip to main content
6.2KVA (PVmax=500V, 48V battery) vs POW-HVM6.2K-PRO (6.2KW) 8 of 17 identical Swap Change inverters

Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6.2K-PRO (6.2KW)

Easun Power 6.2KVA (PVmax=500V, 48V battery)
Easun Power
6.2KVA (PVmax=500V, 48V battery)
6.2 kW Hybrid
VS
Easun Power
POW-HVM6.2K-PRO (6.2KW)
6.2 kW Hybrid
The verdict

6.2KVA (PVmax=500V, 48V battery) leads on the differences that matter

The largest is max efficiency: 1.0 pp more efficient. 8 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
8 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 17 parameters
Parameter 6.2KVA (PVmax=500V, 48V battery) POW-HVM6.2K-PRO (6.2KW) Difference
Max efficiency 94.0 % 93.0 % 1.0 pp more efficient
Max PV power 6.50 kW 6.00 kW 0.50 kW apart
Weight 8.7 kg 10.3 kg 1.6 kg lighter
Max operating temperature 55 °C 50 °C 5 °C more heat tolerant
DC/AC ratio 1.05 0.97 0.08 more oversizing headroom
Weight per kW 1.4 kg/kW 1.7 kg/kW 0.3 kg/kW lighter
MPPT voltage range 60-500 V 60-450 V 60-500 V vs 60-450 V
Battery voltage Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc) Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Dimensions 105x295x438 mm 449x324x136 mm 105x295x438 mm vs 449x324x136 mm
02

Full specification

Parameter 6.2KVA (PVmax=500V, 48V battery) POW-HVM6.2K-PRO (6.2KW) Difference
AC output
Rated AC power 6.20 kW 6.20 kW Same
Max AC power 6.20 kW 6.20 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current - - Neither datasheet publishes this
PV input
Max PV power 6.50 kW 6.00 kW 0.50 kW apart
DC/AC ratio 1.05 0.97 +0.08 for 6.2KVA (PVmax=500V, 48V battery)
Max DC voltage 500 V 500 V Same
MPPT voltage range 60-500 V 60-450 V 60-500 V vs 60-450 V
Start voltage - 60 V Not published by Easun Power
MPP trackers - - Neither datasheet publishes this
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - 27.0 A Not published by Easun Power
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 94.0 % 93.0 % +1.0 pp for 6.2KVA (PVmax=500V, 48V battery)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc) Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Max charge current 120 A 120 A Same
Backup power - 6.2 kW Not published by Easun Power
Physical
Weight 8.7 kg 10.3 kg -1.6 kg for 6.2KVA (PVmax=500V, 48V battery)
Weight per kW 1.4 kg/kW 1.7 kg/kW -0.3 kg/kW for 6.2KVA (PVmax=500V, 48V battery)
Dimensions 105x295x438 mm 449x324x136 mm 105x295x438 mm vs 449x324x136 mm
Ingress protection - - Neither datasheet publishes this
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 50 °C +5 °C for 6.2KVA (PVmax=500V, 48V battery)
Connectivity and safety
Wi-Fi - Yes Not published by Easun Power
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Easun Power
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6200W-48V
One difference: dimensions
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KVA (48V)
3 differences, the largest is weight
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6.2KP
8 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.