Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6.2K-PRO (6.2KW)
VS
The verdict
6.2KVA (PVmax=500V, 48V battery) leads on the differences that matter
The largest is max efficiency: 1.0 pp more efficient. 8 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
8
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 17 parameters
What actually differs
Parameter
6.2KVA (PVmax=500V, 48V battery)
POW-HVM6.2K-PRO (6.2KW)
Difference
Max efficiency
94.0 %
93.0 %
1.0 pp more efficient
Max PV power
6.50 kW
6.00 kW
0.50 kW apart
Weight
8.7 kg
10.3 kg
1.6 kg lighter
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
DC/AC ratio
1.05
0.97
0.08 more oversizing headroom
Weight per kW
1.4 kg/kW
1.7 kg/kW
0.3 kg/kW lighter
MPPT voltage range
60-500 V
60-450 V
60-500 V vs 60-450 V
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Dimensions
105x295x438 mm
449x324x136 mm
105x295x438 mm vs 449x324x136 mm
02
Full specification
Parameter
6.2KVA (PVmax=500V, 48V battery)
POW-HVM6.2K-PRO (6.2KW)
Difference
AC output
Rated AC power
6.20 kW
6.20 kW
Same
Max AC power
6.20 kW
6.20 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
-
-
Neither datasheet publishes this
PV input
Max PV power
6.50 kW
6.00 kW
0.50 kW apart
DC/AC ratio
1.05
0.97
+0.08 for 6.2KVA (PVmax=500V, 48V battery)
Max DC voltage
500 V
500 V
Same
MPPT voltage range
60-500 V
60-450 V
60-500 V vs 60-450 V
Start voltage
-
60 V
Not published by Easun Power
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
27.0 A
Not published by Easun Power
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
94.0 %
93.0 %
+1.0 pp for 6.2KVA (PVmax=500V, 48V battery)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Max charge current
120 A
120 A
Same
Backup power
-
6.2 kW
Not published by Easun Power
Physical
Weight
8.7 kg
10.3 kg
-1.6 kg for 6.2KVA (PVmax=500V, 48V battery)
Weight per kW
1.4 kg/kW
1.7 kg/kW
-0.3 kg/kW for 6.2KVA (PVmax=500V, 48V battery)
Dimensions
105x295x438 mm
449x324x136 mm
105x295x438 mm vs 449x324x136 mm
Ingress protection
-
-
Neither datasheet publishes this
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
55 °C
50 °C
+5 °C for 6.2KVA (PVmax=500V, 48V battery)
Connectivity and safety
Wi-Fi
-
Yes
Not published by Easun Power
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Easun Power
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6200W-48V
One difference: dimensions
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KVA (48V)
3 differences, the largest is weight
Same type, similar size
Easun Power
Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6.2KP
8 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.