Skip to main content
4.2KW vs MIN 4200TL-XA 6 of 15 identical Swap Change inverters

Easun Power 4.2KW vs Growatt MIN 4200TL-XA

Easun Power 4.2KW
Easun Power
4.2KW
4.2 kW Hybrid
VS
Growatt MIN 4200TL-XA
Growatt
MIN 4200TL-XA
4.2 kW 97.2 % euro Hybrid
The verdict

9 differences, and they point both ways

The largest is max efficiency: 5.4 pp more efficient. 6 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
6 of 15 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 15 parameters
Parameter 4.2KW MIN 4200TL-XA Difference
Max efficiency 93.0 % 98.4 % 5.4 pp more efficient
Max charge current 120 A 17 A 103 A faster charging
Weight 8.0 kg 10.8 kg 2.8 kg lighter
Weight per kW 1.9 kg/kW 2.6 kg/kW 0.7 kg/kW lighter
Max operating temperature 50 °C 60 °C 10 °C more heat tolerant
Battery voltage 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 360-550 V 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 360-550 V
Max AC current 18.2 A 19.0 A 0.8 A apart
Dimensions 442x358x116 mm 350x375x160 mm 442x358x116 mm vs 350x375x160 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter 4.2KW MIN 4200TL-XA Difference
AC output
Rated AC power 4.20 kW 4.20 kW Same
Max AC power 4.20 kW 4.20 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 18.2 A 19.0 A 0.8 A apart
PV input
Max PV power 6.20 kW - Not published by Growatt
DC/AC ratio 1.48 - Not published by Growatt
Max DC voltage 500 V - Not published by Growatt
MPPT voltage range 60-500 V - Not published by Growatt
Start voltage - - Neither datasheet publishes this
MPP trackers - - Neither datasheet publishes this
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - - Neither datasheet publishes this
Efficiency
European efficiency - 97.2 % Not published by Easun Power
Max efficiency 93.0 % 98.4 % +5.4 pp for MIN 4200TL-XA
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 360-550 V 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 360-550 V
Max charge current 120 A 17 A +103 A for 4.2KW
Backup power - - Neither datasheet publishes this
Physical
Weight 8.0 kg 10.8 kg -2.8 kg for 4.2KW
Weight per kW 1.9 kg/kW 2.6 kg/kW -0.7 kg/kW for 4.2KW
Dimensions 442x358x116 mm 350x375x160 mm 442x358x116 mm vs 350x375x160 mm
Ingress protection - IP65 Not published by Easun Power
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 50 °C 60 °C +10 °C for MIN 4200TL-XA
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Easun Power
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - 10 yrs Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Easun Power 4.2KW vs Growatt MIN 4200TL-XH
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Easun Power 4.2KW vs Growatt MIN 4200TL-XH2
13 differences, the largest is max dc voltage
Same type, similar size
PowMr
Easun Power 4.2KW vs PowMr SOLXPOW X1-4.2K
7 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.