Easun Power 2KVA (PVmax=160V) vs Easun Power IGrid SV II 1.5KW
VS
The verdict
8 differences, and they point both ways
The largest is max efficiency: 1.0 pp more efficient. 5 of 13 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
5
of 13 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 13 parameters
What actually differs
Parameter
2KVA (PVmax=160V)
IGrid SV II 1.5KW
Difference
Max efficiency
94.0 %
95.0 %
1.0 pp more efficient
Max PV power
0.90 kW
2.00 kW
1.10 kW apart
DC/AC ratio
0.60
1.33
0.73 more oversizing headroom
Weight
5.8 kg
8.0 kg
2.2 kg lighter
Weight per kW
3.9 kg/kW
5.3 kg/kW
1.5 kg/kW lighter
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
48 VDC (nominal)
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 VDC (nominal)
Dimensions
105x295x358 mm
440x300x100 mm
105x295x358 mm vs 440x300x100 mm
02
Full specification
Parameter
2KVA (PVmax=160V)
IGrid SV II 1.5KW
Difference
AC output
Rated AC power
1.50 kW
1.50 kW
Same
Max AC power
1.50 kW
1.50 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
-
6.5 A
Not published by Easun Power
PV input
Max PV power
0.90 kW
2.00 kW
1.10 kW apart
DC/AC ratio
0.60
1.33
+0.73 for IGrid SV II 1.5KW
Max DC voltage
500 V
-
Not published by Easun Power
MPPT voltage range
60-500 V
-
Not published by Easun Power
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
1
Not published by Easun Power
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
94.0 %
95.0 %
+1.0 pp for IGrid SV II 1.5KW
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA)
48 VDC (nominal)
Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 48 VDC (nominal)
Max charge current
120 A
-
Not published by Easun Power
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
5.8 kg
8.0 kg
-2.2 kg for 2KVA (PVmax=160V)
Weight per kW
3.9 kg/kW
5.3 kg/kW
-1.5 kg/kW for 2KVA (PVmax=160V)
Dimensions
105x295x358 mm
440x300x100 mm
105x295x358 mm vs 440x300x100 mm
Ingress protection
-
-
Neither datasheet publishes this
Cooling
forced-air
-
Not published by Easun Power
Noise
-
-
Neither datasheet publishes this
Max operating temperature
55 °C
50 °C
+5 °C for 2KVA (PVmax=160V)
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.