Deye SUN-35K-SG01HP3-EU-BM3 vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
VS
The verdict
SUN-35K-SG01HP3-EU-BM3 leads on the differences that matter
The largest is max dc voltage: 200 V apart. 5 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
5
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 20 parameters
What actually differs
Parameter
SUN-35K-SG01HP3-EU-BM3
WT 35K-H-US L2 / WT 35K-HU-US L2
Difference
Max DC voltage
1000 V
800 V
200 V apart
Max input current per tracker
36.0 A
32.0 A
4.0 A more headroom
Max AC power
38.50 kW
35.00 kW
3.50 kW apart
Max PV power
45.50 kW
75.60 kW
30.10 kW apart
DC/AC ratio
1.30
2.16
0.86 more oversizing headroom
Weight
80.0 kg
133.0 kg
53.0 kg lighter
Weight per kW
2.3 kg/kW
3.8 kg/kW
1.5 kg/kW lighter
Max efficiency
97.6 %
98.0 %
0.4 pp more efficient
Nominal AC voltage
400 V
208 V
192 V apart
Max AC current
58.4 A
106.9 A
48.5 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-850 V
180-600 V
150-850 V vs 180-600 V
Battery voltage
160-800
380-650V
160-800 vs 380-650V
Start voltage
180 V
195 V
15 V earlier start
Dimensions
894x527x294 mm
1350x820x501 mm
894x527x294 mm vs 1350x820x501 mm
02
Full specification
Parameter
SUN-35K-SG01HP3-EU-BM3
WT 35K-H-US L2 / WT 35K-HU-US L2
Difference
AC output
Rated AC power
35.00 kW
35.00 kW
Same
Max AC power
38.50 kW
35.00 kW
3.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
208 V
192 V apart
Max AC current
58.4 A
106.9 A
48.5 A apart
PV input
Max PV power
45.50 kW
75.60 kW
30.10 kW apart
DC/AC ratio
1.30
2.16
+0.86 for WT 35K-H-US L2 / WT 35K-HU-US L2
Max DC voltage
1000 V
800 V
200 V apart
MPPT voltage range
150-850 V
180-600 V
150-850 V vs 180-600 V
Start voltage
180 V
195 V
-15 V for SUN-35K-SG01HP3-EU-BM3
MPP trackers
-
2
Not published by Deye
Strings per tracker
2
-
Not published by Growatt
Max input current per tracker
36.0 A
32.0 A
+4.0 A for SUN-35K-SG01HP3-EU-BM3
Efficiency
European efficiency
97.0 %
-
Not published by Growatt
Max efficiency
97.6 %
98.0 %
+0.4 pp for WT 35K-H-US L2 / WT 35K-HU-US L2
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-800
380-650V
160-800 vs 380-650V
Max charge current
100 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
80.0 kg
133.0 kg
-53.0 kg for SUN-35K-SG01HP3-EU-BM3
Weight per kW
2.3 kg/kW
3.8 kg/kW
-1.5 kg/kW for SUN-35K-SG01HP3-EU-BM3
Dimensions
894x527x294 mm
1350x820x501 mm
894x527x294 mm vs 1350x820x501 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
65 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
5 yrs
-
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Deye SUN-35K-SG01HP3-EU-BM3 vs Ginlong Solis S6-EH3P35K-H-LV(21A)
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Deye SUN-35K-SG01HP3-EU-BM3 vs Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2
7 differences, the largest is weight
Same type, similar size
Growatt
Deye SUN-35K-SG01HP3-EU-BM3 vs Growatt MID 36K-HU
17 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.