Deye SUN-12K-SG01LP1-EU vs Huawei SUN2000-12K-MAP0
VS
The verdict
SUN2000-12K-MAP0 leads on the differences that matter
The largest is european efficiency: 1.7 pp more efficient. 4 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
4
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 23 parameters
What actually differs
Parameter
SUN-12K-SG01LP1-EU
SUN2000-12K-MAP0
Difference
European efficiency
96.5 %
98.2 %
1.7 pp more efficient
Max DC voltage
500 V
1100 V
600 V apart
Max input current per tracker
26.0 A
16.0 A
10.0 A more headroom
Max efficiency
97.6 %
98.6 %
1.0 pp more efficient
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Max PV power
15.60 kW
22.00 kW
6.40 kW apart
DC/AC ratio
1.30
1.83
0.53 more oversizing headroom
Weight
48.5 kg
21.0 kg
27.5 kg lighter
Weight per kW
4.0 kg/kW
1.8 kg/kW
2.3 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
100.0 A
20.2 A
79.8 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
150-425 V
160-1000 V
150-425 V vs 160-1000 V
Battery voltage
40-60
600-980 V
40-60 vs 600-980 V
Start voltage
150 V
160 V
10 V earlier start
Strings per tracker
2
1
1 string apart
Dimensions
798x464x300 mm
490x460x130 mm
798x464x300 mm vs 490x460x130 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SUN-12K-SG01LP1-EU
SUN2000-12K-MAP0
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
100.0 A
20.2 A
79.8 A apart
PV input
Max PV power
15.60 kW
22.00 kW
6.40 kW apart
DC/AC ratio
1.30
1.83
+0.53 for SUN2000-12K-MAP0
Max DC voltage
500 V
1100 V
600 V apart
MPPT voltage range
150-425 V
160-1000 V
150-425 V vs 160-1000 V
Start voltage
150 V
160 V
-10 V for SUN-12K-SG01LP1-EU
MPP trackers
-
2
Not published by Deye
Strings per tracker
2
1
1 string apart
Max input current per tracker
26.0 A
16.0 A
+10.0 A for SUN-12K-SG01LP1-EU
Efficiency
European efficiency
96.5 %
98.2 %
+1.7 pp for SUN2000-12K-MAP0
Max efficiency
97.6 %
98.6 %
+1.0 pp for SUN2000-12K-MAP0
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60
600-980 V
40-60 vs 600-980 V
Max charge current
-
20 A
Not published by Deye
Backup power
12.0 kW
-
Not published by Huawei
Physical
Weight
48.5 kg
21.0 kg
-27.5 kg for SUN2000-12K-MAP0
Weight per kW
4.0 kg/kW
1.8 kg/kW
-2.3 kg/kW for SUN2000-12K-MAP0
Dimensions
798x464x300 mm
490x460x130 mm
798x464x300 mm vs 490x460x130 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
natural
forced-air vs natural
Noise
30 dB
29 dB
Effectively the same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Deye
Ethernet
-
Yes
Not published by Deye
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
-
Yes
Not published by Deye
Warranty
Warranty
5 yrs
-
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Deye SUN-12K-SG01LP1-EU vs Growatt MID 12KTL3-XH
16 differences, the largest is european efficiency
Same type, similar size
Huawei
Deye SUN-12K-SG01LP1-EU vs Huawei SUN5000-12K-MAP0
19 differences, the largest is european efficiency
Same type, similar size
Huawei
Deye SUN-12K-SG01LP1-EU vs Huawei SUN2000-12KTL-M1 (High current version)
18 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000-12K-MAP0 vs Huawei SUN2000-12KTL-M1
13 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.