Skip to main content
SUN-12K-G03 vs MOD 12KTL3-X2(Pro) 8 of 23 identical Swap Change inverters

Deye SUN-12K-G03 vs Growatt MOD 12KTL3-X2(Pro)

Deye SUN-12K-G03
Deye
SUN-12K-G03
12 kW 97.5 % euro Grid-tie
VS
Growatt MOD 12KTL3-X2(Pro)
Growatt
MOD 12KTL3-X2(Pro)
12 kW 98.2 % euro Grid-tie
The verdict

MOD 12KTL3-X2(Pro) leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 8 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
8 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 23 parameters
Parameter SUN-12K-G03 MOD 12KTL3-X2(Pro) Difference
European efficiency 97.5 % 98.2 % 0.7 pp more efficient
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 13.0 A 20.0 A 7.0 A more headroom
Max AC power 13.20 kW 12.00 kW 1.20 kW apart
Max PV power 15.60 kW 18.00 kW 2.40 kW apart
Weight 11.0 kg 15.6 kg 4.6 kg lighter
DC/AC ratio 1.30 1.50 0.20 more oversizing headroom
Max efficiency 98.3 % 98.6 % 0.3 pp more efficient
Max operating temperature 65 °C 60 °C 5 °C more heat tolerant
Weight per kW 0.9 kg/kW 1.3 kg/kW 0.4 kg/kW lighter
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 120-850 V 140-1000 V 120-850 V vs 140-1000 V
Start voltage 140 V 160 V 20 V earlier start
Max AC current 19.1 A 20.0 A 0.9 A apart
Dimensions 457x330x205 mm 387x425x178 mm 457x330x205 mm vs 387x425x178 mm
02

Full specification

Parameter SUN-12K-G03 MOD 12KTL3-X2(Pro) Difference
AC output
Rated AC power 12.00 kW 12.00 kW Same
Max AC power 13.20 kW 12.00 kW 1.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 19.1 A 20.0 A 0.9 A apart
PV input
Max PV power 15.60 kW 18.00 kW 2.40 kW apart
DC/AC ratio 1.30 1.50 +0.20 for MOD 12KTL3-X2(Pro)
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 120-850 V 140-1000 V 120-850 V vs 140-1000 V
Start voltage 140 V 160 V -20 V for SUN-12K-G03
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 20.0 A +7.0 A for MOD 12KTL3-X2(Pro)
Efficiency
European efficiency 97.5 % 98.2 % +0.7 pp for MOD 12KTL3-X2(Pro)
Max efficiency 98.3 % 98.6 % +0.3 pp for MOD 12KTL3-X2(Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 11.0 kg 15.6 kg -4.6 kg for SUN-12K-G03
Weight per kW 0.9 kg/kW 1.3 kg/kW -0.4 kg/kW for SUN-12K-G03
Dimensions 457x330x205 mm 387x425x178 mm 457x330x205 mm vs 387x425x178 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise 25 dB - Not published by Growatt
Max operating temperature 65 °C 60 °C +5 °C for SUN-12K-G03
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Deye
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - 8 yrs Not published by Deye
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Deye SUN-12K-G03 vs Growatt MOD 12KTL3-X
16 differences, the largest is european efficiency
Same type, similar size
Sungrow
Deye SUN-12K-G03 vs Sungrow SG12KTL-M
12 differences, the largest is european efficiency
Same type, similar size
Sungrow
Deye SUN-12K-G03 vs Sungrow SG12RT-20
13 differences, the largest is european efficiency
Same type, similar size
GoodWe
Growatt MOD 12KTL3-X2(Pro) vs GoodWe GW12KLN-DT
9 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.