Deye SUN-10K-SG01HP3-EU-AM2 vs Huawei SUN2000-10KTL-M1
VS
The verdict
SUN2000-10KTL-M1 leads on the differences that matter
The largest is european efficiency: 1.1 pp more efficient. 12 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
12
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 27 parameters
What actually differs
Parameter
SUN-10K-SG01HP3-EU-AM2
SUN2000-10KTL-M1
Difference
European efficiency
97.0 %
98.1 %
1.1 pp more efficient
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
26.0 A
11.0 A
15.0 A more headroom
Max efficiency
97.6 %
98.6 %
1.0 pp more efficient
Max PV power
13.00 kW
15.00 kW
2.00 kW apart
Max charge current
50 A
16 A
34 A faster charging
Weight
30.5 kg
17.0 kg
13.5 kg lighter
Weight per kW
3.0 kg/kW
1.7 kg/kW
1.3 kg/kW lighter
DC/AC ratio
1.30
1.50
0.20 more oversizing headroom
Max AC current
18.7 A
16.9 A
1.8 A apart
MPPT voltage range
150-850 V
140-980 V
150-850 V vs 140-980 V
Start voltage
180 V
200 V
20 V earlier start
Battery voltage
160-700
600 V ~ 980 V
160-700 vs 600 V ~ 980 V
Strings per tracker
2
1
1 string apart
Dimensions
638x408x237 mm
525x470x146 mm
638x408x237 mm vs 525x470x146 mm
02
Full specification
Parameter
SUN-10K-SG01HP3-EU-AM2
SUN2000-10KTL-M1
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
11.00 kW
11.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
18.7 A
16.9 A
1.8 A apart
PV input
Max PV power
13.00 kW
15.00 kW
2.00 kW apart
DC/AC ratio
1.30
1.50
+0.20 for SUN2000-10KTL-M1
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
150-850 V
140-980 V
150-850 V vs 140-980 V
Start voltage
180 V
200 V
-20 V for SUN-10K-SG01HP3-EU-AM2
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
26.0 A
11.0 A
+15.0 A for SUN-10K-SG01HP3-EU-AM2
Efficiency
European efficiency
97.0 %
98.1 %
+1.1 pp for SUN2000-10KTL-M1
Max efficiency
97.6 %
98.6 %
+1.0 pp for SUN2000-10KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
160-700
600 V ~ 980 V
160-700 vs 600 V ~ 980 V
Max charge current
50 A
16 A
+34 A for SUN-10K-SG01HP3-EU-AM2
Backup power
-
3.3 kW
Not published by Deye
Physical
Weight
30.5 kg
17.0 kg
-13.5 kg for SUN2000-10KTL-M1
Weight per kW
3.0 kg/kW
1.7 kg/kW
-1.3 kg/kW for SUN2000-10KTL-M1
Dimensions
638x408x237 mm
525x470x146 mm
638x408x237 mm vs 525x470x146 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
55 dB
-
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Deye SUN-10K-SG01HP3-EU-AM2 vs SolarEdge SE10000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Deye SUN-10K-SG01HP3-EU-AM2 vs Growatt MOD 10KTL3-XH
15 differences, the largest is european efficiency
Same type, similar size
Growatt
Deye SUN-10K-SG01HP3-EU-AM2 vs Growatt MOD 10KTL3-HU
19 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000-10KTL-M1 vs Huawei SUN2000-10KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.