Deye SUN-100K-G03 vs Sungrow SG110CX
VS
The verdict
SUN-100K-G03 leads on the differences that matter
The largest is max dc voltage: 100 V apart. 11 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
11
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 20 parameters
What actually differs
Parameter
SUN-100K-G03
SG110CX
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
26.0 A
14.0 A more headroom
Weight
81.0 kg
89.0 kg
8.0 kg lighter
European efficiency
98.3 %
98.5 %
0.2 pp more efficient
Max AC current
166.7 A
158.8 A
7.9 A apart
Max operating temperature
65 °C
60 °C
5 °C more heat tolerant
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
200-850 V
200-1000 V
200-850 V vs 200-1000 V
Dimensions
568x838x346 mm
660x1051x362 mm
568x838x346 mm vs 660x1051x362 mm
02
Full specification
Parameter
SUN-100K-G03
SG110CX
Difference
AC output
Rated AC power
100.00 kW
100.00 kW
Same
Max AC power
110.00 kW
110.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
166.7 A
158.8 A
7.9 A apart
PV input
Max PV power
150.00 kW
-
Not published by Sungrow
DC/AC ratio
1.50
-
Not published by Sungrow
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
200-850 V
200-1000 V
200-850 V vs 200-1000 V
Start voltage
250 V
250 V
Same
MPP trackers
-
9
Not published by Deye
Strings per tracker
-
2
Not published by Deye
Max input current per tracker
40.0 A
26.0 A
+14.0 A for SUN-100K-G03
Efficiency
European efficiency
98.3 %
98.5 %
+0.2 pp for SG110CX
Max efficiency
98.8 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
81.0 kg
89.0 kg
-8.0 kg for SUN-100K-G03
Weight per kW
0.8 kg/kW
0.9 kg/kW
Effectively the same
Dimensions
568x838x346 mm
660x1051x362 mm
568x838x346 mm vs 660x1051x362 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Sungrow
Max operating temperature
65 °C
60 °C
+5 °C for SUN-100K-G03
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Deye SUN-100K-G03 vs Huawei SUN2000-100KTL-M2
10 differences, the largest is max dc voltage
Same type, similar size
Huawei
Deye SUN-100K-G03 vs Huawei SUN2000-100KTL-M1 (@480 V)
10 differences, the largest is max dc voltage
Same type, similar size
SMA Solar
Deye SUN-100K-G03 vs SMA Solar Sunny Highpower PEAK3 SHP 100-21
11 differences, the largest is max dc voltage
Same type, similar size
SMA Solar
Sungrow SG110CX vs SMA Solar Sunny Highpower Storage SHPS 100-21
6 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.