Skip to main content
VSUN700N-132BMH-DG vs VSUN470N-120BMH-DG-BB 7 of 19 identical Swap Change panels

VSUN VSUN700N-132BMH-DG vs VSUN VSUN470N-120BMH-DG-BB

VSUN
VSUN700N-132BMH-DG
700 Wp 22.53 % TOPCon Bifacial
VS
VSUN
VSUN470N-120BMH-DG-BB
470 Wp 21.72 % TOPCon Bifacial
The verdict

VSUN700N-132BMH-DG leads on the differences that matter

The largest is module efficiency: 0.81 pp more efficient. 7 of 19 comparable parameters are identical.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs
01

What actually differs

12 of 19 parameters
Parameter VSUN700N-132BMH-DG VSUN470N-120BMH-DG-BB Difference
Module efficiency 22.53 % 21.72 % 0.81 pp more efficient
Rated power 700 Wp 470 Wp 230 W more power
Weight 38.5 kg 26.7 kg 11.8 kg lighter
Product warranty 12 yrs 25 yrs 13 yrs longer
Power density 225.3 Wp/m² 217.2 Wp/m² 8.1 Wp/m² higher
Open-circuit voltage 48.50 V 42.37 V 6.13 V apart
Short-circuit current 18.32 A 14.15 A 4.17 A apart
Module area 3.106 m² 2.164 m² 0.943 m² apart
Voltage at max power 40.50 V 35.07 V 5.43 V apart
Current at max power 17.29 A 13.41 A 3.88 A apart
Cell count 132 120 12 cells apart
Dimensions 2384x1303x35 mm 1908x1134x30 mm 2384x1303x35 mm vs 1908x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.300 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
VSUN700N-132BMH-DG
23,486 kWh
VSUN470N-120BMH-DG-BB
15,769 kWh
Lifetime gap
7,717 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario VSUN700N-132BMH-DG VSUN470N-120BMH-DG-BB
Standard test conditions 25 °C 100.0% of rated power 700 W 470 W
Cool, bright day 40 °C 95.5% of rated power 669 W 449 W
Typical summer roof 55 °C 91.0% of rated power 637 W 428 W
Hot roof 70 °C 86.5% of rated power 606 W 407 W
03

Full specification

Parameter VSUN700N-132BMH-DG VSUN470N-120BMH-DG-BB Difference
Power and efficiency
Rated power 700 Wp 470 Wp +230 W for VSUN700N-132BMH-DG
Module efficiency 22.53 % 21.72 % +0.81 pp for VSUN700N-132BMH-DG
Power density 225.3 Wp/m² 217.2 Wp/m² +8.1 Wp/m² for VSUN700N-132BMH-DG
Open-circuit voltage 48.50 V 42.37 V 6.13 V apart
Voltage at max power 40.50 V 35.07 V 5.43 V apart
Short-circuit current 18.32 A 14.15 A 4.17 A apart
Current at max power 17.29 A 13.41 A 3.88 A apart
Temperature
Temperature coefficient -0.300 %/°C -0.300 %/°C Same
Mechanical
Dimensions 2384x1303x35 mm 1908x1134x30 mm 2384x1303x35 mm vs 1908x1134x30 mm
Module area 3.106 m² 2.164 m² 0.943 m² apart
Weight 38.5 kg 26.7 kg -11.8 kg for VSUN470N-120BMH-DG-BB
Weight per kWp 55.0 kg/kWp 56.8 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 25 yrs +13 yrs for VSUN470N-120BMH-DG-BB
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 120 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#3,982 vs #7,399
VSUN700N-132BMH-DG leads by 3,417 places
Power density
#3,989 vs #7,384
VSUN700N-132BMH-DG leads by 3,395 places
Heat behaviour
#6,093 vs #6,093
Tied - the same position in the database
Weight
#9,361 vs #10,872
VSUN700N-132BMH-DG leads by 1,511 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#1,197 vs #6,515
VSUN700N-132BMH-DG leads by 5,318 places
05

More useful comparisons

Open the full database
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN715N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN710N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN705N-132BMHT-DG
The same specification on paper
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN700N-132BMHT-DG
The same specification on paper
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN695N-132BMH-DG
The same specification on paper
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN695N-132BMHT-DG
The same specification on paper
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: VSUN VSUN700N-132BMH-DG or VSUN VSUN470N-120BMH-DG-BB?
According to our database: VSUN VSUN700N-132BMH-DG has higher module efficiency (22.53% vs 21.72%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of VSUN VSUN700N-132BMH-DG and VSUN VSUN470N-120BMH-DG-BB?
VSUN VSUN700N-132BMH-DG has a module efficiency of 22.53%, while VSUN VSUN470N-120BMH-DG-BB is 21.72%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does VSUN VSUN700N-132BMH-DG use vs VSUN VSUN470N-120BMH-DG-BB?
VSUN VSUN700N-132BMH-DG uses TOPCon cells; VSUN VSUN470N-120BMH-DG-BB uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on VSUN VSUN700N-132BMH-DG and VSUN VSUN470N-120BMH-DG-BB?
VSUN VSUN700N-132BMH-DG has a 30 years power warranty; VSUN VSUN470N-120BMH-DG-BB has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are VSUN VSUN700N-132BMH-DG and VSUN VSUN470N-120BMH-DG-BB bifacial panels?
Both VSUN VSUN700N-132BMH-DG and VSUN VSUN470N-120BMH-DG-BB are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 3 VSUN offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.