Gokin GK-4-78HGBD-775M vs Recom RCM-720-8DBNM
VS
The verdict
GK-4-78HGBD-775M leads on the differences that matter
The largest is module efficiency: 0.90 pp more efficient. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
GK-4-78HGBD-775M
RCM-720-8DBNM
Difference
Module efficiency
24.10 %
23.20 %
0.90 pp more efficient
Rated power
775 Wp
720 Wp
55 W more power
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
0.030 %/°C better in heat
Power density
241.3 Wp/m²
231.8 Wp/m²
9.5 Wp/m² higher
Product warranty
15 yrs
30 yrs
15 yrs longer
Open-circuit voltage
58.82 V
49.23 V
9.59 V apart
Module area
3.212 m²
3.106 m²
0.106 m² apart
Short-circuit current
16.71 A
18.54 A
1.83 A apart
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Annual degradation
0.35 %/yr
0.40 %/yr
0.05 %/yr slower
Voltage at max power
48.87 V
41.10 V
7.77 V apart
Cell count
156
132
24 cells apart
Weight per kWp
49.9 kg/kWp
52.5 kg/kWp
2.6 kg/kWp lighter
Current at max power
15.86 A
17.52 A
1.66 A apart
Dimensions
2465x1303x33 mm
2384x1303x33 mm
2465x1303x33 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
GK-4-78HGBD-775M
26,205 kWh
RCM-720-8DBNM
24,157 kWh
Lifetime gap
2,048 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
GK-4-78HGBD-775M
RCM-720-8DBNM
Standard test conditions
25 °C
100.0% of rated power
775 W
720 W
Cool, bright day
40 °C
95.7% of rated power
745 W
689 W
Typical summer roof
55 °C
91.3% of rated power
715 W
657 W
Hot roof
70 °C
87.0% of rated power
684 W
626 W
03
Full specification
Parameter
GK-4-78HGBD-775M
RCM-720-8DBNM
Difference
Power and efficiency
Rated power
775 Wp
720 Wp
+55 W for GK-4-78HGBD-775M
Module efficiency
24.10 %
23.20 %
+0.90 pp for GK-4-78HGBD-775M
Power density
241.3 Wp/m²
231.8 Wp/m²
+9.5 Wp/m² for GK-4-78HGBD-775M
Open-circuit voltage
58.82 V
49.23 V
9.59 V apart
Voltage at max power
48.87 V
41.10 V
7.77 V apart
Short-circuit current
16.71 A
18.54 A
1.83 A apart
Current at max power
15.86 A
17.52 A
1.66 A apart
Temperature
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
+0.030 %/°C for GK-4-78HGBD-775M
Mechanical
Dimensions
2465x1303x33 mm
2384x1303x33 mm
2465x1303x33 mm vs 2384x1303x33 mm
Module area
3.212 m²
3.106 m²
0.106 m² apart
Weight
38.7 kg
37.8 kg
Effectively the same
Weight per kWp
49.9 kg/kWp
52.5 kg/kWp
-2.6 kg/kWp for GK-4-78HGBD-775M
Warranty and degradation
Product warranty
15 yrs
30 yrs
+15 yrs for RCM-720-8DBNM
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.35 %/yr
0.40 %/yr
-0.05 %/yr for GK-4-78HGBD-775M
Technology
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
156
132
24 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#219
vs
#1,306
GK-4-78HGBD-775M leads by 1,087 places
Power density
#227
vs
#1,347
GK-4-78HGBD-775M leads by 1,120 places
Heat behaviour
#511
vs
#2,165
GK-4-78HGBD-775M leads by 1,654 places
Weight
#3,297
vs
#6,043
GK-4-78HGBD-775M leads by 2,746 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#29
vs
#23
RCM-720-8DBNM leads by 6 places
05
Open the full database
More useful comparisons
Same series, other bin
Gokin
Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-780M
One difference: module efficiency
Same series, other bin
Gokin
Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-770M
The same specification on paper
Same series, other bin
Gokin
Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-765M
3 differences, the largest is module efficiency
Same series, other bin
Gokin
Gokin GK-4-78HGBD-775M vs Gokin GK-4-78HGBD-760M
3 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-720-8DBNM vs Recom RCM-730-8DBNM
3 differences, the largest is module efficiency
Same series, other bin
Recom
Recom RCM-720-8DBNM vs Recom RCM-725-8DBNM
The same specification on paper
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Gokin GK-4-78HGBD-775M or Recom RCM-720-8DBNM?
According to our database: Gokin GK-4-78HGBD-775M has higher module efficiency (24.10% vs 23.20%); Gokin GK-4-78HGBD-775M tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM?
Gokin GK-4-78HGBD-775M has a module efficiency of 24.10%, while Recom RCM-720-8DBNM is 23.20%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Gokin GK-4-78HGBD-775M use vs Recom RCM-720-8DBNM?
Gokin GK-4-78HGBD-775M uses Back Contact cells; Recom RCM-720-8DBNM uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM?
Gokin GK-4-78HGBD-775M has a 30 years power warranty; Recom RCM-720-8DBNM has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM bifacial panels?
Both Gokin GK-4-78HGBD-775M and Recom RCM-720-8DBNM are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 7 Gokin offers · See 3 Recom offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.

