Skip to main content
GCL-NT12R/54GDF-530 vs NT12R/48GDF-455W 9 of 19 identical Swap Change panels

GCL GCL-NT12R/54GDF-530 vs GCL NT12R/48GDF-455W

GCL-NT12R/54GDF-530
530 Wp 23.82 % TOPCon Bifacial
VS
NT12R/48GDF-455W
455 Wp 22.77 % TOPCon Bifacial
The verdict

GCL-NT12R/54GDF-530 leads on the differences that matter

The largest is module efficiency: 1.05 pp more efficient. 9 of 19 comparable parameters are identical.

See all 10 differences
How alike are they
9 of 19 comparable
parameters are identical
identical differs
01

What actually differs

10 of 19 parameters
Parameter GCL-NT12R/54GDF-530 NT12R/48GDF-455W Difference
Module efficiency 23.82 % 22.77 % 1.05 pp more efficient
Rated power 530 Wp 455 Wp 75 W more power
Power density 238.2 Wp/m² 227.7 Wp/m² 10.5 Wp/m² higher
Weight 27.3 kg 24.5 kg 2.8 kg lighter
Open-circuit voltage 40.55 V 35.30 V 5.25 V apart
Module area 2.225 m² 1.998 m² 0.227 m² apart
Voltage at max power 34.42 V 29.94 V 4.48 V apart
Cell count 108 96 12 cells apart
Weight per kWp 51.5 kg/kWp 53.8 kg/kWp 2.3 kg/kWp lighter
Dimensions 1962x1134x30 mm 1762x1134x30 mm 1962x1134x30 mm vs 1762x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
GCL-NT12R/54GDF-530
17,783 kWh
NT12R/48GDF-455W
15,266 kWh
Lifetime gap
2,517 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario GCL-NT12R/54GDF-530 NT12R/48GDF-455W
Standard test conditions 25 °C 100.0% of rated power 530 W 455 W
Cool, bright day 40 °C 95.7% of rated power 507 W 435 W
Typical summer roof 55 °C 91.3% of rated power 484 W 415 W
Hot roof 70 °C 87.0% of rated power 461 W 396 W
03

Full specification

Parameter GCL-NT12R/54GDF-530 NT12R/48GDF-455W Difference
Power and efficiency
Rated power 530 Wp 455 Wp +75 W for GCL-NT12R/54GDF-530
Module efficiency 23.82 % 22.77 % +1.05 pp for GCL-NT12R/54GDF-530
Power density 238.2 Wp/m² 227.7 Wp/m² +10.5 Wp/m² for GCL-NT12R/54GDF-530
Open-circuit voltage 40.55 V 35.30 V 5.25 V apart
Voltage at max power 34.42 V 29.94 V 4.48 V apart
Short-circuit current 16.21 A 16.00 A Effectively the same
Current at max power 15.40 A 15.20 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1962x1134x30 mm 1762x1134x30 mm 1962x1134x30 mm vs 1762x1134x30 mm
Module area 2.225 m² 1.998 m² 0.227 m² apart
Weight 27.3 kg 24.5 kg -2.8 kg for NT12R/48GDF-455W
Weight per kWp 51.5 kg/kWp 53.8 kg/kWp -2.3 kg/kWp for GCL-NT12R/54GDF-530
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 96 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#418 vs #3,073
GCL-NT12R/54GDF-530 leads by 2,655 places
Power density
#451 vs #2,888
GCL-NT12R/54GDF-530 leads by 2,437 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#4,879 vs #7,897
GCL-NT12R/54GDF-530 leads by 3,018 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#4,679 vs #8,644
GCL-NT12R/54GDF-530 leads by 3,965 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54GDF-525W
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL GCL-NT12R/54GDF-525
One difference: module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54BGDF-520W
5 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54GDF-520W
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL GCL-NT12R/54GDF-520
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/54GDF-530 vs GCL NT12R/54BGDF-515W
5 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NT12R/54GDF-530 or GCL NT12R/48GDF-455W?
According to our database: GCL GCL-NT12R/54GDF-530 has higher module efficiency (23.82% vs 22.77%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/54GDF-530 and GCL NT12R/48GDF-455W?
GCL GCL-NT12R/54GDF-530 has a module efficiency of 23.82%, while GCL NT12R/48GDF-455 W is 22.77%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/54GDF-530 use vs GCL NT12R/48GDF-455W?
GCL GCL-NT12R/54GDF-530 uses TOPCon cells; GCL NT12R/48GDF-455 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/54GDF-530 and GCL NT12R/48GDF-455W?
GCL GCL-NT12R/54GDF-530 has a 30 years power warranty; GCL NT12R/48GDF-455 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/54GDF-530 and GCL NT12R/48GDF-455W bifacial panels?
Both GCL GCL-NT12R/54GDF-530 and GCL NT12R/48GDF-455 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 5 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.