Skip to main content
450 vs 445 18 of 19 identical Swap Change panels

GCL GCL-NT12R/48BGDF-450 vs GCL GCL-NT12R/48BGDF-445

GCL-NT12R/48BGDF-450
450 Wp 22.52 % TOPCon Bifacial
VS
GCL-NT12R/48BGDF-445
445 Wp 22.27 % TOPCon Bifacial
The verdict

450 leads on the differences that matter

The largest is module efficiency: 0.25 pp more efficient. 18 of 19 comparable parameters are identical.

See the one difference
How alike are they
18 of 19 comparable
parameters are identical
identical differs
01

What actually differs

1 of 19 parameters
Parameter 450 445 Difference
Module efficiency 22.52 % 22.27 % 0.25 pp more efficient
02

What it means on a roof

Thirty years of production
Declared annual degradation, with a 1.0% first-year loss assumed for both panels because at least one datasheet omits it, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
450
15,098 kWh
445
14,931 kWh
Lifetime gap
167 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 450 445
Standard test conditions 25 °C 100.0% of rated power 450 W 445 W
Cool, bright day 40 °C 95.7% of rated power 430 W 426 W
Typical summer roof 55 °C 91.3% of rated power 411 W 406 W
Hot roof 70 °C 87.0% of rated power 391 W 387 W
03

Full specification

Parameter 450 445 Difference
Power and efficiency
Rated power 450 Wp 445 Wp Effectively the same
Module efficiency 22.52 % 22.27 % +0.25 pp for 450
Power density 225.2 Wp/m² 222.7 Wp/m² Effectively the same
Open-circuit voltage 35.98 V 35.68 V Effectively the same
Voltage at max power 30.45 V 30.15 V Effectively the same
Short-circuit current 15.52 A 15.50 A Effectively the same
Current at max power 14.78 A 14.76 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1762x1134x30 mm 1762x1134x30 mm Same
Module area 1.998 m² 1.998 m² Same
Weight 21.5 kg 21.5 kg Same
Weight per kWp 47.8 kg/kWp 48.3 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 96 96 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#4,108 vs #5,481
450 leads by 1,373 places
Power density
#4,225 vs #5,302
450 leads by 1,077 places
Heat behaviour
#2,165 vs #2,165
Tied - the same position in the database
Weight
#1,891 vs #2,192
450 leads by 301 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,989 vs #9,381
450 leads by 392 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-520W
10 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-515W
10 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-510W
10 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-505W
8 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-500W
8 differences, the largest is rated power
Same series, other bin
GCL GCL-NT12R/48BGDF-450 vs GCL NT12R/54BGDF-495W
9 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NT12R/48BGDF-450 or GCL GCL-NT12R/48BGDF-445?
According to our database: GCL GCL-NT12R/48BGDF-450 has higher module efficiency (22.52% vs 22.27%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12R/48BGDF-450 and GCL GCL-NT12R/48BGDF-445?
GCL GCL-NT12R/48BGDF-450 has a module efficiency of 22.52%, while GCL GCL-NT12R/48BGDF-445 is 22.27%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12R/48BGDF-450 use vs GCL GCL-NT12R/48BGDF-445?
GCL GCL-NT12R/48BGDF-450 uses TOPCon cells; GCL GCL-NT12R/48BGDF-445 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12R/48BGDF-450 and GCL GCL-NT12R/48BGDF-445?
GCL GCL-NT12R/48BGDF-450 has a 30 years power warranty; GCL GCL-NT12R/48BGDF-445 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12R/48BGDF-450 and GCL GCL-NT12R/48BGDF-445 bifacial panels?
Both GCL GCL-NT12R/48BGDF-450 and GCL GCL-NT12R/48BGDF-445 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.