Skip to main content
NT12/66GDF-730 vs M10/72GDF-B-550 6 of 19 identical Swap Change panels

GCL GCL-NT12/66GDF-730 vs GCL GCL-M10/72GDF-B-550

GCL GCL-NT12/66GDF-730
GCL-NT12/66GDF-730
730 Wp 23.50 % TOPCon Bifacial
VS
GCL-M10/72GDF-B-550
550 Wp 21.00 % PERC Bifacial
The verdict

NT12/66GDF-730 leads on the differences that matter

The largest is module efficiency: 2.50 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter NT12/66GDF-730 M10/72GDF-B-550 Difference
Module efficiency 23.50 % 21.00 % 2.50 pp more efficient
Temperature coefficient -0.290 %/°C -0.350 %/°C 0.060 %/°C better in heat
Rated power 730 Wp 550 Wp 180 W more power
Power density 235.0 Wp/m² 209.6 Wp/m² 25.4 Wp/m² higher
Weight 38.2 kg 33.2 kg 5.0 kg lighter
Weight per kWp 52.3 kg/kWp 60.4 kg/kWp 8.0 kg/kWp lighter
Short-circuit current 18.64 A 13.88 A 4.76 A apart
Module area 3.106 m² 2.624 m² 0.482 m² apart
Cell technology TOPCon PERC TOPCon vs PERC
Current at max power 17.71 A 13.12 A 4.59 A apart
Cell count 132 144 12 cells apart
Annual degradation 0.40 %/yr 0.45 %/yr 0.05 %/yr slower
Dimensions 2384x1303x33 mm 2290x1146x30 mm 2384x1303x33 mm vs 2290x1146x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
NT12/66GDF-730
24,493 kWh
M10/72GDF-B-550
18,112 kWh
Lifetime gap
6,381 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario NT12/66GDF-730 M10/72GDF-B-550
Standard test conditions 25 °C 100.0% of rated power 730 W 550 W
Cool, bright day 40 °C 94.8% of rated power 698 W 521 W
Typical summer roof 55 °C 89.5% of rated power 666 W 492 W
Hot roof 70 °C 84.2% of rated power 635 W 463 W
03

Full specification

Parameter NT12/66GDF-730 M10/72GDF-B-550 Difference
Power and efficiency
Rated power 730 Wp 550 Wp +180 W for NT12/66GDF-730
Module efficiency 23.50 % 21.00 % +2.50 pp for NT12/66GDF-730
Power density 235.0 Wp/m² 209.6 Wp/m² +25.4 Wp/m² for NT12/66GDF-730
Open-circuit voltage 49.02 V 49.80 V Effectively the same
Voltage at max power 41.22 V 41.93 V Effectively the same
Short-circuit current 18.64 A 13.88 A 4.76 A apart
Current at max power 17.71 A 13.12 A 4.59 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.350 %/°C +0.060 %/°C for NT12/66GDF-730
Mechanical
Dimensions 2384x1303x33 mm 2290x1146x30 mm 2384x1303x33 mm vs 2290x1146x30 mm
Module area 3.106 m² 2.624 m² 0.482 m² apart
Weight 38.2 kg 33.2 kg -5.0 kg for M10/72GDF-B-550
Weight per kWp 52.3 kg/kWp 60.4 kg/kWp -8.0 kg/kWp for NT12/66GDF-730
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.45 %/yr -0.05 %/yr for NT12/66GDF-730
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 132 144 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#716 vs #9,758
NT12/66GDF-730 leads by 9,042 places
Power density
#800 vs #9,926
NT12/66GDF-730 leads by 9,126 places
Heat behaviour
#2,165 vs #10,419
NT12/66GDF-730 leads by 8,254 places
Weight
#5,805 vs #12,444
NT12/66GDF-730 leads by 6,639 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#312 vs #7,387
NT12/66GDF-730 leads by 7,075 places
05

More useful comparisons

Open the full database
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-740
3 differences, the largest is module efficiency
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-735
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL NT12/66GDF-730
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF-725
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL NT12/66GDF-725
The same specification on paper
Same series, other bin
GCL GCL-NT12/66GDF-730 vs GCL GCL-NT12/66GDF 725
The same specification on paper
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: GCL GCL-NT12/66GDF-730 or GCL GCL-M10/72GDF-B-550?
According to our database: GCL GCL-NT12/66GDF-730 has higher module efficiency (23.50% vs 21.00%); GCL GCL-NT12/66GDF-730 tolerates heat better (temp coeff -0.290%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of GCL GCL-NT12/66GDF-730 and GCL GCL-M10/72GDF-B-550?
GCL GCL-NT12/66GDF-730 has a module efficiency of 23.50%, while GCL GCL-M10/72GDF-B-550 is 21.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does GCL GCL-NT12/66GDF-730 use vs GCL GCL-M10/72GDF-B-550?
GCL GCL-NT12/66GDF-730 uses TOPCon cells; GCL GCL-M10/72GDF-B-550 uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on GCL GCL-NT12/66GDF-730 and GCL GCL-M10/72GDF-B-550?
GCL GCL-NT12/66GDF-730 has a 30 years power warranty; GCL GCL-M10/72GDF-B-550 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are GCL GCL-NT12/66GDF-730 and GCL GCL-M10/72GDF-B-550 bifacial panels?
Both GCL GCL-NT12/66GDF-730 and GCL GCL-M10/72GDF-B-550 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 6 GCL offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.