Skip to main content
680NT66-HU/BF-DG vs 670M66-HUV 7 of 19 identical Swap Change panels

EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-670M66-HUV

EGing PV
EG-680NT66-HU/BF-DG
680 Wp 21.89 % TOPCon Bifacial
VS
EGing PV EG-670M66-HUV
EGing PV
EG-670M66-HUV
670 Wp 21.56 % PERC
The verdict

680NT66-HU/BF-DG leads on the differences that matter

The largest is temperature coefficient: 0.040 %/°C better in heat. 7 of 19 comparable parameters are identical.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs
01

What actually differs

12 of 19 parameters
Parameter 680NT66-HU/BF-DG 670M66-HUV Difference
Temperature coefficient -0.300 %/°C -0.340 %/°C 0.040 %/°C better in heat
Performance warranty 30 yrs 25 yrs 5 yrs longer
Annual degradation 0.40 %/yr 0.55 %/yr 0.15 %/yr slower
Weight 38.3 kg 32.9 kg 5.4 kg lighter
Weight per kWp 56.3 kg/kWp 49.1 kg/kWp 7.2 kg/kWp lighter
Module efficiency 21.89 % 21.56 % 0.33 pp more efficient
Cell technology TOPCon PERC TOPCon vs PERC
Power density 218.9 Wp/m² 215.7 Wp/m² 3.2 Wp/m² higher
Rated power 680 Wp 670 Wp 10 W more power
Bifacial Yes No Yes vs No
Open-circuit voltage 47.43 V 45.97 V 1.46 V apart
Voltage at max power 39.63 V 38.16 V 1.47 V apart
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
680NT66-HU/BF-DG
22,815 kWh
670M66-HUV
21,714 kWh
Lifetime gap
1,101 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 680NT66-HU/BF-DG 670M66-HUV
Standard test conditions 25 °C 100.0% of rated power 680 W 670 W
Cool, bright day 40 °C 94.9% of rated power 649 W 636 W
Typical summer roof 55 °C 89.8% of rated power 619 W 602 W
Hot roof 70 °C 84.7% of rated power 588 W 567 W
03

Full specification

Parameter 680NT66-HU/BF-DG 670M66-HUV Difference
Power and efficiency
Rated power 680 Wp 670 Wp +10 W for 680NT66-HU/BF-DG
Module efficiency 21.89 % 21.56 % +0.33 pp for 680NT66-HU/BF-DG
Power density 218.9 Wp/m² 215.7 Wp/m² +3.2 Wp/m² for 680NT66-HU/BF-DG
Open-circuit voltage 47.43 V 45.97 V 1.46 V apart
Voltage at max power 39.63 V 38.16 V 1.47 V apart
Short-circuit current 18.18 A 18.61 A Effectively the same
Current at max power 17.16 A 17.56 A Effectively the same
Temperature
Temperature coefficient -0.300 %/°C -0.340 %/°C +0.040 %/°C for 680NT66-HU/BF-DG
Mechanical
Dimensions 2384x1303x35 mm 2384x1303x35 mm Same
Module area 3.106 m² 3.106 m² Same
Weight 38.3 kg 32.9 kg -5.4 kg for 670M66-HUV
Weight per kWp 56.3 kg/kWp 49.1 kg/kWp -7.2 kg/kWp for 670M66-HUV
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 25 yrs +5 yrs for 680NT66-HU/BF-DG
Annual degradation 0.40 %/yr 0.55 %/yr -0.15 %/yr for 680NT66-HU/BF-DG
Technology
Cell technology TOPCon PERC TOPCon vs PERC
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes No Yes vs No
04

Against the whole database

14,005 panels
Efficiency
#6,882 vs #7,774
680NT66-HU/BF-DG leads by 892 places
Power density
#6,804 vs #7,644
680NT66-HU/BF-DG leads by 840 places
Heat behaviour
#6,093 vs #8,778
680NT66-HU/BF-DG leads by 2,685 places
Weight
#10,599 vs #2,745
670M66-HUV leads by 7,854 places
Warranty
#21 vs #9,798
680NT66-HU/BF-DG leads by 9,777 places
Overall
#1,923 vs #3,378
680NT66-HU/BF-DG leads by 1,455 places
05

More useful comparisons

Open the full database
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-685NT66-HU/BF-DG
The same specification on paper
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-675NT66-HU/BF-DG
The same specification on paper
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-670NT66-HU/BF-DG
3 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-665NT66-HU/BF-DG
3 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-660NT66-HU/BF-DG
3 differences, the largest is module efficiency
Same series, other bin
EGing PV
EGing PV EG-680NT66-HU/BF-DG vs EGing PV EG-620NT60-HU/BF-DG
7 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: EGing PV EG-680NT66-HU/BF-DG or EGing PV EG-670M66-HUV?
According to our database: EGing PV EG-680NT66-HU/BF-DG has higher module efficiency (21.89% vs 21.56%); EGing PV EG-680NT66-HU/BF-DG tolerates heat better (temp coeff -0.300%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of EGing PV EG-680NT66-HU/BF-DG and EGing PV EG-670M66-HUV?
EGing PV EG-680NT66-HU/BF-DG has a module efficiency of 21.89%, while EGing PV EG-670M66-HUV is 21.56%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does EGing PV EG-680NT66-HU/BF-DG use vs EGing PV EG-670M66-HUV?
EGing PV EG-680NT66-HU/BF-DG uses TOPCon cells; EGing PV EG-670M66-HUV uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on EGing PV EG-680NT66-HU/BF-DG and EGing PV EG-670M66-HUV?
EGing PV EG-680NT66-HU/BF-DG has a 30 years power warranty; EGing PV EG-670M66-HUV has a 25 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are EGing PV EG-680NT66-HU/BF-DG and EGing PV EG-670M66-HUV bifacial panels?
EGing PV EG-680NT66-HU/BF-DG is bifacial (captures light from both faces); EGing PV EG-670M66-HUV is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 3 EGing PV offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.