Skip to main content
670M66-HUV vs 590M60-HU/BF-DG 6 of 19 identical Swap Change panels

EGing PV EG-670M66-HUV vs EGing PV EG-590M60-HU/BF-DG

EGing PV EG-670M66-HUV
EGing PV
EG-670M66-HUV
670 Wp 21.56 % PERC
VS
EGing PV EG-590M60-HU/BF-DG
EGing PV
EG-590M60-HU/BF-DG
590 Wp 20.84 % PERC Bifacial
The verdict

670M66-HUV leads on the differences that matter

The largest is module efficiency: 0.72 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter 670M66-HUV 590M60-HU/BF-DG Difference
Module efficiency 21.56 % 20.84 % 0.72 pp more efficient
Rated power 670 Wp 590 Wp 80 W more power
Performance warranty 25 yrs 30 yrs 5 yrs longer
Weight per kWp 49.1 kg/kWp 59.3 kg/kWp 10.2 kg/kWp lighter
Power density 215.7 Wp/m² 208.5 Wp/m² 7.2 Wp/m² higher
Annual degradation 0.55 %/yr 0.45 %/yr 0.10 %/yr slower
Open-circuit voltage 45.97 V 41.31 V 4.66 V apart
Module area 3.106 m² 2.830 m² 0.276 m² apart
Weight 32.9 kg 35.0 kg 2.1 kg lighter
Cell count 132 120 12 cells apart
Voltage at max power 38.16 V 34.21 V 3.95 V apart
Bifacial No Yes No vs Yes
Dimensions 2384x1303x35 mm 2172x1303x35 mm 2384x1303x35 mm vs 2172x1303x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.340 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
670M66-HUV
21,714 kWh
590M60-HU/BF-DG
19,429 kWh
Lifetime gap
2,285 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 670M66-HUV 590M60-HU/BF-DG
Standard test conditions 25 °C 100.0% of rated power 670 W 590 W
Cool, bright day 40 °C 94.9% of rated power 636 W 560 W
Typical summer roof 55 °C 89.8% of rated power 602 W 530 W
Hot roof 70 °C 84.7% of rated power 567 W 500 W
03

Full specification

Parameter 670M66-HUV 590M60-HU/BF-DG Difference
Power and efficiency
Rated power 670 Wp 590 Wp +80 W for 670M66-HUV
Module efficiency 21.56 % 20.84 % +0.72 pp for 670M66-HUV
Power density 215.7 Wp/m² 208.5 Wp/m² +7.2 Wp/m² for 670M66-HUV
Open-circuit voltage 45.97 V 41.31 V 4.66 V apart
Voltage at max power 38.16 V 34.21 V 3.95 V apart
Short-circuit current 18.61 A 18.30 A Effectively the same
Current at max power 17.56 A 17.25 A Effectively the same
Temperature
Temperature coefficient -0.340 %/°C -0.340 %/°C Same
Mechanical
Dimensions 2384x1303x35 mm 2172x1303x35 mm 2384x1303x35 mm vs 2172x1303x35 mm
Module area 3.106 m² 2.830 m² 0.276 m² apart
Weight 32.9 kg 35.0 kg -2.1 kg for 670M66-HUV
Weight per kWp 49.1 kg/kWp 59.3 kg/kWp -10.2 kg/kWp for 670M66-HUV
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 25 yrs 30 yrs +5 yrs for 590M60-HU/BF-DG
Annual degradation 0.55 %/yr 0.45 %/yr -0.10 %/yr for 590M60-HU/BF-DG
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 132 120 12 cells apart
Bifacial No Yes No vs Yes
04

Against the whole database

14,005 panels
Efficiency
#7,774 vs #10,421
670M66-HUV leads by 2,647 places
Power density
#7,644 vs #10,359
670M66-HUV leads by 2,715 places
Heat behaviour
#8,778 vs #8,778
Tied - the same position in the database
Weight
#2,745 vs #12,099
670M66-HUV leads by 9,354 places
Warranty
#9,798 vs #21
590M60-HU/BF-DG leads by 9,777 places
Overall
#3,378 vs #6,044
670M66-HUV leads by 2,666 places
05

More useful comparisons

Open the full database
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-685NT66-HU/BF-DG
12 differences, the largest is temperature coefficient
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-680NT66-HU/BF-DG
12 differences, the largest is temperature coefficient
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-675NT66-HU/BF-DG
9 differences, the largest is temperature coefficient
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-670NT66-HU/BF-DG
10 differences, the largest is temperature coefficient
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-670M66-HU/BF-DG
5 differences, the largest is performance warranty
Same series, other bin
EGing PV
EGing PV EG-670M66-HUV vs EGing PV EG-665NT66-HU/BF-DG
9 differences, the largest is temperature coefficient
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: EGing PV EG-670M66-HUV or EGing PV EG-590M60-HU/BF-DG?
According to our database: EGing PV EG-670M66-HUV has higher module efficiency (21.56% vs 20.84%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of EGing PV EG-670M66-HUV and EGing PV EG-590M60-HU/BF-DG?
EGing PV EG-670M66-HUV has a module efficiency of 21.56%, while EGing PV EG-590M60-HU/BF-DG is 20.84%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does EGing PV EG-670M66-HUV use vs EGing PV EG-590M60-HU/BF-DG?
EGing PV EG-670M66-HUV uses PERC cells; EGing PV EG-590M60-HU/BF-DG uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on EGing PV EG-670M66-HUV and EGing PV EG-590M60-HU/BF-DG?
EGing PV EG-670M66-HUV has a 25 years power warranty; EGing PV EG-590M60-HU/BF-DG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are EGing PV EG-670M66-HUV and EGing PV EG-590M60-HU/BF-DG bifacial panels?
EGing PV EG-590M60-HU/BF-DG is bifacial (captures light from both faces); EGing PV EG-670M66-HUV is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.

Shop prices: See 3 EGing PV offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.