Astronergy CHSM54N(BL)-HC 420W vs JA Solar JAM54D41-455/LR
VS
The verdict
JAM54D41-455/LR leads on the differences that matter
The largest is module efficiency: 1.30 pp more efficient. 9 of 19 comparable parameters are identical.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
10 of 19 parameters
What actually differs
Parameter
CHSM54N(BL)-HC 420W
JAM54D41-455/LR
Difference
Module efficiency
21.50 %
22.80 %
1.30 pp more efficient
Power density
215.1 Wp/m²
227.7 Wp/m²
12.6 Wp/m² higher
Rated power
420 Wp
455 Wp
35 W more power
Open-circuit voltage
38.00 V
40.50 V
2.50 V apart
Module area
1.953 m²
1.998 m²
0.045 m² apart
Weight per kWp
50.7 kg/kWp
48.4 kg/kWp
2.4 kg/kWp lighter
Short-circuit current
13.87 A
14.42 A
0.55 A apart
Dimensions
1722x1134x30 mm
1762x1134x30 mm
1722x1134x30 mm vs 1762x1134x30 mm
Voltage at max power
31.93 V
33.33 V
1.40 V apart
Current at max power
13.15 A
13.65 A
0.50 A apart
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
CHSM54N(BL)-HC 420W
14,092 kWh
JAM54D41-455/LR
15,266 kWh
Lifetime gap
1,174 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
CHSM54N(BL)-HC 420W
JAM54D41-455/LR
Standard test conditions
25 °C
100.0% of rated power
420 W
455 W
Cool, bright day
40 °C
95.7% of rated power
402 W
435 W
Typical summer roof
55 °C
91.3% of rated power
383 W
415 W
Hot roof
70 °C
87.0% of rated power
365 W
396 W
03
Full specification
Parameter
CHSM54N(BL)-HC 420W
JAM54D41-455/LR
Difference
Power and efficiency
Rated power
420 Wp
455 Wp
+35 W for JAM54D41-455/LR
Module efficiency
21.50 %
22.80 %
+1.30 pp for JAM54D41-455/LR
Power density
215.1 Wp/m²
227.7 Wp/m²
+12.6 Wp/m² for JAM54D41-455/LR
Open-circuit voltage
38.00 V
40.50 V
2.50 V apart
Voltage at max power
31.93 V
33.33 V
1.40 V apart
Short-circuit current
13.87 A
14.42 A
0.55 A apart
Current at max power
13.15 A
13.65 A
0.50 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1722x1134x30 mm
1762x1134x30 mm
1722x1134x30 mm vs 1762x1134x30 mm
Module area
1.953 m²
1.998 m²
0.045 m² apart
Weight
21.3 kg
22.0 kg
Effectively the same
Weight per kWp
50.7 kg/kWp
48.4 kg/kWp
-2.4 kg/kWp for JAM54D41-455/LR
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
No
No
Same
04
14,005 panels
Against the whole database
Efficiency
#7,958
vs
#2,714
JAM54D41-455/LR leads by 5,244 places
Power density
#7,882
vs
#2,888
JAM54D41-455/LR leads by 4,994 places
Heat behaviour
#2,165
vs
#2,165
Tied - the same position in the database
Weight
#4,124
vs
#2,220
JAM54D41-455/LR leads by 1,904 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#10,214
vs
#7,813
JAM54D41-455/LR leads by 2,401 places
05
Open the full database
More useful comparisons
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy CHSM54N-HC-445
7 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy CHSM54N-HC-445W
6 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy ASTRO N5s CHSM54N-HC-445W
6 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy CHSM54N-HC-440
5 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy CHSM54N-HC-440W
4 differences, the largest is module efficiency
Same series, other bin
Astronergy CHSM54N(BL)-HC 420W vs Astronergy CHSM54N(BL)-HC 440W
4 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Astronergy CHSM54N(BL)-HC 420W or JA Solar JAM54D41-455/LR?
According to our database: JA Solar JAM54D41-455/LR has higher module efficiency (22.80% vs 21.50%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Astronergy CHSM54N(BL)-HC 420W and JA Solar JAM54D41-455/LR?
Astronergy CHSM54N(BL)-HC 420 W has a module efficiency of 21.50%, while JA Solar JAM54D41-455/LR is 22.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Astronergy CHSM54N(BL)-HC 420W use vs JA Solar JAM54D41-455/LR?
Astronergy CHSM54N(BL)-HC 420 W uses TOPCon cells; JA Solar JAM54D41-455/LR uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Astronergy CHSM54N(BL)-HC 420W and JA Solar JAM54D41-455/LR?
Astronergy CHSM54N(BL)-HC 420 W has a 30 years power warranty; JA Solar JAM54D41-455/LR has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Shop prices: See 41 Astronergy offers · See 384 JA Solar offers