AIKO AIKO-A800-GRH78Dw vs Recom RCM-725-8DBNM
VS
The verdict
AIKO-A800-GRH78Dw leads on the differences that matter
The largest is module efficiency: 1.60 pp more efficient. 3 of 18 comparable parameters are identical, with 1 more left out because at least one datasheet does not publish it.
See all 15 differencesHow alike are they
3
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 18 parameters
What actually differs
Parameter
AIKO-A800-GRH78Dw
RCM-725-8DBNM
Difference
Module efficiency
24.90 %
23.30 %
1.60 pp more efficient
Rated power
800 Wp
725 Wp
75 W more power
Power density
249.1 Wp/m²
233.4 Wp/m²
15.7 Wp/m² higher
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
0.030 %/°C better in heat
Product warranty
15 yrs
30 yrs
15 yrs longer
Open-circuit voltage
59.32 V
49.41 V
9.91 V apart
Module area
3.212 m²
3.106 m²
0.106 m² apart
Short-circuit current
17.06 A
18.64 A
1.58 A apart
Weight
39.8 kg
37.8 kg
2.0 kg lighter
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Voltage at max power
49.36 V
41.27 V
8.09 V apart
Cell count
156
132
24 cells apart
Weight per kWp
49.7 kg/kWp
52.1 kg/kWp
2.4 kg/kWp lighter
Current at max power
16.21 A
17.57 A
1.36 A apart
Dimensions
2465x1303x33 mm
2384x1303x33 mm
2465x1303x33 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
AIKO-A800-GRH78Dw
26,842 kWh
RCM-725-8DBNM
24,325 kWh
Lifetime gap
2,517 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
AIKO-A800-GRH78Dw
RCM-725-8DBNM
Standard test conditions
25 °C
100.0% of rated power
800 W
725 W
Cool, bright day
40 °C
95.7% of rated power
769 W
693 W
Typical summer roof
55 °C
91.3% of rated power
738 W
662 W
Hot roof
70 °C
87.0% of rated power
706 W
630 W
03
Full specification
Parameter
AIKO-A800-GRH78Dw
RCM-725-8DBNM
Difference
Power and efficiency
Rated power
800 Wp
725 Wp
+75 W for AIKO-A800-GRH78Dw
Module efficiency
24.90 %
23.30 %
+1.60 pp for AIKO-A800-GRH78Dw
Power density
249.1 Wp/m²
233.4 Wp/m²
+15.7 Wp/m² for AIKO-A800-GRH78Dw
Open-circuit voltage
59.32 V
49.41 V
9.91 V apart
Voltage at max power
49.36 V
41.27 V
8.09 V apart
Short-circuit current
17.06 A
18.64 A
1.58 A apart
Current at max power
16.21 A
17.57 A
1.36 A apart
Temperature
Temperature coefficient
-0.260 %/°C
-0.290 %/°C
+0.030 %/°C for AIKO-A800-GRH78Dw
Mechanical
Dimensions
2465x1303x33 mm
2384x1303x33 mm
2465x1303x33 mm vs 2384x1303x33 mm
Module area
3.212 m²
3.106 m²
0.106 m² apart
Weight
39.8 kg
37.8 kg
-2.0 kg for RCM-725-8DBNM
Weight per kWp
49.7 kg/kWp
52.1 kg/kWp
-2.4 kg/kWp for AIKO-A800-GRH78Dw
Warranty and degradation
Product warranty
15 yrs
30 yrs
+15 yrs for RCM-725-8DBNM
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
-
0.40 %/yr
Not published by AIKO
Technology
Cell technology
Back Contact
TOPCon
Back Contact vs TOPCon
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
156
132
24 cells apart
Bifacial
Yes
Yes
Same
04
14,005 panels
Against the whole database
Efficiency
#10
vs
#1,017
AIKO-A800-GRH78Dw leads by 1,007 places
Power density
#10
vs
#936
AIKO-A800-GRH78Dw leads by 926 places
Heat behaviour
#511
vs
#2,165
AIKO-A800-GRH78Dw leads by 1,654 places
Weight
#3,214
vs
#5,609
AIKO-A800-GRH78Dw leads by 2,395 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#2
vs
#14
AIKO-A800-GRH78Dw leads by 12 places
05
Open the full database
More useful comparisons
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A805-GRH78Dw
One difference: module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A795-GRH78Dw
The same specification on paper
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A790-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A785-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A780-GRH78Dw
3 differences, the largest is module efficiency
Same series, other bin
AIKO AIKO-A800-GRH78Dw vs AIKO AIKO-A775-GRH78Dw
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: AIKO AIKO-A800-GRH78Dw or Recom RCM-725-8DBNM?
According to our database: AIKO AIKO-A800-GRH78Dw has higher module efficiency (24.90% vs 23.30%); AIKO AIKO-A800-GRH78Dw tolerates heat better (temp coeff -0.260%/°C vs -0.290%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of AIKO AIKO-A800-GRH78Dw and Recom RCM-725-8DBNM?
AIKO AIKO-A800-GRH78Dw has a module efficiency of 24.90%, while Recom RCM-725-8DBNM is 23.30%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does AIKO AIKO-A800-GRH78Dw use vs Recom RCM-725-8DBNM?
AIKO AIKO-A800-GRH78Dw uses Back Contact cells; Recom RCM-725-8DBNM uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on AIKO AIKO-A800-GRH78Dw and Recom RCM-725-8DBNM?
AIKO AIKO-A800-GRH78Dw has a 30 years power warranty; Recom RCM-725-8DBNM has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are AIKO AIKO-A800-GRH78Dw and Recom RCM-725-8DBNM bifacial panels?
Both AIKO AIKO-A800-GRH78Dw and Recom RCM-725-8DBNM are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 180 AIKO offers · See 3 Recom offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.